  1. K

    Ideal Boiler Fault

    dhw thermistors are rubbish on these , try replacing it, sounds like its reading the wrong resistances, .I have had new ones fail on me before.
  2. K

    Can I make wireless digistat 2 drive a new Ideal Isar boiler

    couldnt agree more......Iss anything ....shivers doon yer spine
  3. K

    Ideal Istor HE260 HE325 Loud Bang + More

    interested to know ....... glass ball , ive had these ideal diverters in bits a lot cant say ive seen any glass balls.... would love to know where it is??
  4. K

    Potterton Puma 80e

    Straight short from top left of main pcb , check for burning , every other puma has or will have this fault. If all heating controls, timeclock etc are off and fuse still blows check this as it isnt calling for anything its just the power supply to the main pcb shorting to earth. Check for...
  5. K

    Saunier Duval thema classic F24E losing pressure

    Very common fault is that the spindle in the filling valve ( the blue handle) breaks internally and leaves the seat jammed in the valve so no water can pass into the boiler through the non return valve( the brass cylindrical bit at the end of the short copper pipe). Easy repair , new filling...
  6. K

    Ideal Isar 30100 fan, how to test, coil resistance, 5 wires

    approximately 130 ohms through the 2 outside terminals on the plug on the fan, yours sounds ok , dont bother about the others they are for speed control according to demand . These pcbs are very bad for packing up for no outwardly obvious reason along with a whole lot of other problems.... not...
  7. K

    Ideal Classic Boiler/New Pump/Airlock?

    Classic air locking of cold feed from F&e tank, try opening the heating system drain and drain off some water to get the water moving down the cold feed into the system, remember to bleed the pump through its rotor end screw, if that doesnt allow gravity to kick in and fill the system then there...
  8. K

    External boiler locating advice needed

    Go to a web site such as Worcester or the manufacturer of the boiler you want to buy and download the appropriate boiler installation manual, doesnt have to be the exact model as all the flue positioning , ventilation etc should be in the installation manual. and is pretty generic or just phone...
  9. K

    Problems with Ideal Isar HE30

    Check your spark electrode gaps , very common to be warped out of shape with heat, very common also are internal heat exchanger leaks interrupting combustion or light up process. Gas pressures whilst running should be zero whilst running showing gas valve is delivering right mixture according...
  10. K

    Ideal ISAR m30100 PCB settings

    Pressure problems are certainly nothing to do with pcb link positions... the boiler just wouldnt fire if they were wrong , it just throws up an error message on the digital display. If no obvious system leaks around radiators and pipework etc check you arent losing it through the prv to...
  11. K

    Potterton Profile 80e sometimes not firing up

    Pcb glitch, verrry common on profiles, dry joints on pcb , not reading pilot flame presence etc etc
  12. K

    Glowworm Micron 40ff problem

    yep..... switched live in motorised valve a bit dodgy or not opening at all on occasion
  13. K

    Ariston Microcombi 23 MFFI (or 1)

    Thermistor problem...... cuts them out and makes them stand still, check with meter on 20k scale resistance, if its open circuit on either heating or hot water thermistor nothing happens .... it just sits waiting.
  14. K

    Halstead "ACE" Not Hot Water

    Listen to the man ..... he be correct, diaphragm very cheap bit of rubber
  15. K

    vokera mynute 14-48se not lighting

    verrry strange , are you getting a flame????, if you are opening and closing the yellow handle underneath it should have no effect on anything as far as switching boiler on and off, that handle shuts gas off.
  16. K

    Entry to a Powermax 155x

    Fraid he is .......... burner comes out the top and ALWAYS needs new gaskets or it leaks combustion back into the room, even the electrodes dont come out without the burner coming out and its possible they just need the gap adjusting........... great design by boiler folk and builders!!
  17. K

    Worcester 240 Combi

    I agrre , the PCBs on most older Worcesters suffer from dry joints which chuck up wierd and wonderful symptoms ie boiler working when you press the pcb down with a screwdriver but stopping when you let go , the pump plugs and mains connections are favourites........ only way to sort is replace...
  18. K

    vokera mynute 14-48se not lighting

    Probably the pump differential pressure switch not being activated, possibly faulty diaphragm or air in diaphragm housing. Check that the swoitch is moving when the boiler is switched on off, pump runs anyway when power switched on and controls asking for heat , the switch activates the rest of...
  19. K

    boiler trouble

    Even Ideal give up on this one.......... they change the entire Hydraulic pack ie the entire plastic bits under the combustion chamber, pump, diverter etc etc , thats how they are assembled so they get the lot assembled and put it all in as one............ funny how it cures the problem but they...
  20. K

    Boilermate ii gledhill boiler buzzing

    Done tons of these on Boilermate 2 s , nearly always the delay timer buzzing, thats the bottom one, it activates when a demand is asked of the boiler and its pump overrun after temp satisfied then the buzzing stops ....... For some reason nearly all of these are installed in bedroom cupboards...