  1. F

    Ariston Micro Genus 27 MFFI locking Out

    when i say lower it i mean connect it back onto the pipe but lower down
  2. F

    Ariston Micro Genus 27 MFFI locking Out

    try this, on the left hand pipe from the heat exchanger you will see an overheat stat on a clip on the pipe remove it and lower it about level with the burner this normally fixes the problem good luck
  3. F

    Potterton 50 lockout

    tak a look at BBC WATCHDOG put in pott suprima and you may get a surprise potterton now do a fixed fee repair on this troublesome boiler good luck
  4. F

    microgenus 23 hot water fault

    the problem is that the domestic hot water heat exchanger has muck in it you will have to get it exchanged and possibly get the system flushed as the muck comes from the central heating circuit if you install a new boiler later this year you will need to get the system flushed for this anyway...
  5. F

    Microgenus Divertor Query

    yes you can change the guts of the diverter it just a sring and valve body they swell and let by good luck
  6. F

    Potterton Suprima 30L and Boilermate 2000 Hell

    try changing the thermista in the boiler these cost about 12 quid and just push in with 2 wire spades on this may work as it should have been changed with the pcb and gas valve/ good luck
  7. F

    Euro Combi sx20 PCB

    your problem could also be the air pressure switch breaking down for various reasons its a cheaper option but you are not allowed to fix it unless you are corgi registerd so you would be better off finding a gas engineer sorry
  8. F

    Odd Suprima behaviour

    the prob could be the gas valve as they have had a problem when the pcb goes wrong it messes up the electrics in the gas valve have a look at BBC WATCHDOG potterton suprima you might get a supprise.
  9. F

    ICOS HE24

    ideal do have a problem with boilers like yours as they fitted wrong washers in the boilers on a six week run 2 years ago and some of them have been leaking there response has been pretty poor to the problem so if it is leaking from the boiler it is probably the wrong o ring seals .good luck.
  10. F

    Central Heating problem

    it could also be a faulty rad valve not letting enough water through
  11. F

    Radiator TRV Advice

    you dont have to put trv on every rad if a room does not get hot with the rad thats in it then putting a trv on it wont make any differance at all you only need to fit them in rooms that get to hot but under the new building regs of 2006 they have to be fitted in bedrooms on replacement of the...
  12. F

    can we change to a combi?

    even if you have a one pipe system you can still put a combie on it with no problem as long as the system is powerflushed properly it should be ok the only prob is some older systems dont like being pressurised and may leak so it a good idea to check the condition of the rads and valves good luck
  13. F

    Potterton Suprima 40 Amber light - Please help!!!

    these boilers have a manufacturers fault go to BBC.WATCHDOG ,and enter potterton suprima you will get a nice surprise as potterton have now agrred to fix the problems, at cost.
  14. F

    Ariston Micro Genus HE32 MFFI pressure problem

    the two thing you descibe are not connected to each other,if the condense water does not get away the drain is blocked this would stop the boiler working,but it is probably because you have not got water in the system you should have 1 bar on the pressure gauge to start check out side to see if...
  15. F

    Urgent Help Needed. Worcester 28 CDI stopped working!

    check that you have water in the sytem look at the bar pressure gauge should be 1 to 1.5 bar when cold if there is no water in it it want work good luck, the gauge is on the boiler.
  16. F

    Cold radiators downstairs

    you say you have drained the system before so i assume that it filled up ok this being the case the fault is probably because you have magnatite or sludge in the down stairs rads if there is no drain cock you will have to drain each rad into a bowl then remove them to the garsen and wash them...
  17. F

    How do I increase the pressure on Ariston micro genus boiler

    under the boiler you will have either 2 blue knobs or 2 black ones ,if blue undo both and the water will fill the system NOTE there is a design fault with the blue ones if you undo it to far it could come of in your hand and mains water will go everywhere,if black turn each one a quarter turn to...
  18. F

    Ariston Micro genus losing pressure

    when you turn the tap on and it leaks is normal for this tap its a design fault.you are loosin pressure either because you have a water leak somewhere and then refiiling the system.or check outside is the prv pipe through the wall dripping if so the pressure vessel in the boiler may have ran out...
  19. F

    Ariston Micro Genus 23

    the problem is the pcb when you have fitted the new one you will see 6 little white pegs on the left of the pcb move 4 5 6 over to the left and it will be fine.