Search results

  1. T

    Minor works certs in factories

    I figured as much, and saved me a lot of hassle trying to get the whole thing isolated for testing :D Thanks
  2. T

    Minor works certs in factories

    If i am tapping off a canalis 40A busbar with a single phase 10A fused spur, does this require a minor works cert? There are various tap-offs which supply computers etc, so its a bit inconvenient to switch off to do full testing of the busbar IR and R1/R2 measures etc What is the...
  3. T

    Clean Earth

    Thankyou, another day older, and slightly wiserer :lol:
  4. T

    Clean Earth

    Thanks Chri5 so the socket on page 355 of the screfix cat advertised as a 2 gang surge and Clean Earth is aload of bull
  5. T

    Clean Earth

    can someone explain what a clean earth is, when I search for answers all I get is stuff about saving the planet. Such as Surge protected clean earth socket outlet?
  6. T

    Meter removal

    If that is the case the wall can stay
  7. T

    Meter removal

    Shikes!, a big rubber gimp suit no doubt, I'd want paying a lot of money to do that too :shock:
  8. T

    Meter removal

    I dont wish to hijack your thread, but I too was considering a wall removal which will involve the meter being moved, it will also involve the incomer being extended to get to the new location, do you think they will do this? I presume they will have to switch off the whole street to do this...
  9. T

    Floodlights.... which ones give an orange light

    Hi Norv, please consider the information here when installing the lighting http://www.britastro.org/dark-skies/ Ade
  10. T

    Numerical Conductors in SWA

    Thanks people, I was indeed enquiring about all black numbered conductors, as it happened I used 1 for phase, 2- N and Y/G -CPC, sleeved them so I guess I was OK. Thanks for the replies.
  11. T

    Numerical Conductors in SWA

    Are there any regulations regarding which numbered conductors to use for P, N, or CPC when using single phase, or is it just a case of sheathing the conductors with the appropriate sleeves? Thanks Ade
  12. T

    Which MFT?

    Thanks for the replies, Its a big investment so I want to be sure that I am not buying a turkey. I do like the look and feel of the meggers, I just now need to weed through the different versions, is there a comparison web site anywhere? Thanks again forthe replies, this is a very friendly...
  13. T

    Which MFT?

    I am looking to buy a MFT but am unsure which direction to go, they all seem to offer the appropriate test functions so your experience of the different makes would be appreciated Megger, Robin/Fluke or Alphatek? all comments appreciated Thanks Ade
  14. T

    What's wrong with this then?????????????

    It dosent really matter what colour the sheath of the cable is, as long as the conductors are corrrectly identified within, and the correct plug/socket for the intended voltage is used
Back