  1. B

    Replacing gas fire coals without manual

    Go on the cc part mate you'll get a response on there as you are an rgi
  2. B

    Biasi 24S safety thermostat tripping on CH

    the readings will drop quickly after tripping as pump overrun occurs to drop temps in boiler for safety. burner cuts out immediatly after overheat, pump continues to run to disperse heat into system, thus dropping temp+ resistance readings. ps. if temperature+ resistances rising after overheat...
  3. B

    Biasi 24S safety thermostat tripping on CH

    if overheat stat hasn't been changed after tripping so may times then it could now be tripping at a lower temperature(nuisance tripping), try changing this, if not then pump could be worn(reason for spindle not rising fully) or restrictions in boiler, as you've said plate was dirty. p.s...
  4. B

    radiators hot, water only lukewarm

    is your heating on when you are using your hot water? agree with gordengas get bg out as they'll always advise a new boiler cause of it's age(if it's 12 to 15 yrs old, so if parts are available then it should be fixed
  5. B

    Alpha CB24/28 Losing Pressure

    have you checked the prv pipe outside is not dripping when boiler is pressurised?
  6. B

    BAXI 105e hot water problems

    hi mate, is your kitchen sink further away than your bathroom taps?, possibly just the hot water diaphragm stretched/holed!
  7. B

    Baxi 105 HE pressure problems??

    hi dude, think you missed a bit, she said dripping from plastic pipe
  8. B

    Who can fit a boiler for me in the East Cornwall area please

    clearly, why dont you try the" i dont want to pay much for work that needs a qualified engineer to do cos i'll do most of the work and take out most of the profit that the engineer relies on to run a business" forum!!!!!!!!! do you take your car to a tyre garage and say " yes mate just bring me...
  9. B

    Who can fit a boiler for me in the East Cornwall area please

    do you not realise that this guy quoting you is a fully trained, qualified prob time served gas engineer trying to run a business/earn his living??? there you go trying to make him do his job for a minute proportion of what he could normally get on other jobs. you're having a laugh :evil:
  10. B

    Worcester Bosch fires on, off, on off, - any ideas?

    yes but it's best to get rgi to check it out as they will know how to check it to confirm resistances.
  11. B

    Worcester Bosch fires on, off, on off, - any ideas?

    most likely could be central heating sensor faulty
  12. B

    Modena 80E Boiler lock out!

    all problems leading to those symptoms require an rgi to diagnose and fix, cos they require accessing electrics and combustion chamber,
  13. B

    help needed worcester 24cdi

    as jamespl said most likely diverter valve or diaphgram
  14. B

    Cold radiator with hot supply present and a TRV pin up?

    take off lockshield valves to confirm you have flow through both sides of rad
  15. B

    How to reduce pressure of Worcester Greenstar combi boiler?

    who is your service with, cos i would probably phone them and tell them you have a problem, cos they can then make the time available to attend to the problem as well as the service, cos they will only be expecting time for the service on the job.
  16. B

    Ideal Classic NF 50 boiler

    it will still spark if no gas, as boiler cant identify gas flow but, if you can affect it by banging on the control box then pos pcb/aps faulty, you need to confirm 240v at gas valve when fault occurs, if 240v present then gas valve at fault, but get a gas engineer in to fix!
  17. B

    How to reduce pressure of Worcester Greenstar combi boiler?

    depends if your filling loop is external or not, but going on your thread it should be the silver braided pipe connecting two pipes, it is this braided pipe you need to remove by unscrewing it off each valve it connects to,you may need some pliers to start it off! make sure your only undoing the...
  18. B

    Slight condensation from flue pipe

    yeh mate, thats why the flue should be level, cos if rain water drives at the flue terminal and the flue is at an angle then, the rain flows back towards boiler via the air duct and then drips down through flue brackets and onto boiler casing!
  19. B

    Slight condensation from flue pipe

    i know BONKERS REALLY :roll: :lol:
  20. B

    Ideal Classic NF 50 boiler

    can you hear the ignition giving a steady clicking when attempting to light? also when was the boiler serviced last? cos the pilot may need cleaning out.