Search results

  1. G

    New boiler

    Alot of places do finance , was just wondering if you get better price for cash , the place I was looking at is the glasgow boiler company
  2. G

    New boiler

    Hey guys . I have a glowworm fuel saver 3, its a g rated boiler , it feeds 4 radiators and a towel rail. , everything uses 8mm apart from towel rail , thats 15mm. The boiler will come on for 1 min , then go off for a min , and repeat this process and it takes 1 hr to go up 1 degree. The...
  3. G

    Resin garden

    Im thinking of doing a resin patio and driveway. At the rear its full of weeds and the monoblock on drive way has weeds growing through them and blocks have had there day . So was thinking of doing resin . Is it correct to dig all the grass out down to a depth of about 4 inches. Mix up...
  4. G

    Central heating pipes and rads

    Im wanting to upgrade my central heating before I get a new boiler fitted . What I have just now is 2 rows of 15mm copper pipe running under floor with no installation. (Flow and return) From each piece it feeds 4 radiators from 1985 with microbore pipe , think its 8mm. The boiler is having...
  5. G

    Ford fiesta mk7 heater and clicking

    Hi . I've a fiesta mk7 tdci titanium 2009 with automatic climate control. From behind the dash is 2 clicking noises . One just behind the controls and one sounds further back . It started the heating wouldn't come through the blowers at any force. Just footwell. And was working on all...
  6. G

    candy grand o vita heatpump

    I wish I never got it. And at 3 hrs to dry clothes. Of u have 2 loads. That' 6 hrs. Compared to about 3 on a ordinary one .
  7. G

    candy grand o vita heatpump

    The filters I have found are . The one in door . And one in front of condenser. It' black plastic with foam inside. I them vacuumed the condenser and washed (insitu). The door water container used to get lots of water . And emptied / cleaned after every cycle. Then it stopped collecting...
  8. G

    candy grand o vita heatpump

    I'l give it a try . Thanks . But if that fails then I will need to check it. If water ain't getting to the tank then could be pump . Many got fluff in it
  9. G

    candy grand o vita heatpump

    It' just out with its warranty period of about 4 month. My stupid wife didn' bother registering the warranty for the 10 years parts
  10. G

    candy grand o vita heatpump

    is there a diagnostic/test mode on this machine. if so how is it accsessed
  11. G

    candy grand o vita heatpump

    Thanks for reply. When u open door the clothes are warm but wet. And all the hot steam has steamed up viewing window and the windows in kitchen . It hasn' come up any error codes
  12. G

    candy grand o vita heatpump

    hi guys got the.candy heatpump dryer.9kg. its just over year old not used much as i usually stick clothes on clothes horse when i dry a load (about 3kg). the water tank does not collect water. and it steams windows up. and.any program. including 40 min rapid . they are still damp. filters...
  13. G

    Bosh oven front glass

    Hi I'm looking for.a front replacement glass for the oven door. The model is hba63b2.2b I've looked online and can't see one that's like mine. It has two aluminium strips up the sides where the glass is . And it uses white location rubber grommets to a fix to the frame. Glass is black in...
  14. G

    Gw fulesaver f35

    The coupling. Unscrewed both sides . Side at igniter I put the probes and other side I heat up the end of it. Just trying to eliminate things that are diy acceptable to fix. That's the most common problem I've read about about boilers not working. Everything clicks on. The pump and fan.
  15. G

    Gw fulesaver f35

    Ahh OK thanks. Found one online £25. What's the best way to test these without a tester. I tryed multimeter set to mv connected to one side, heat the others side up but meter reads 0.
  16. G

    Gw fulesaver f35

    Won't a universal one do from plumb centre or screwfix .
  17. G

    Gw fulesaver f35

    I'm wondering if it would be the thermocoupler . I know sometimes that's the culprit for non spark . I haven't got £160 for a call out . And it would be double time at weekend. I'm doing easy stuff to eliminate that. If those don't work then no hot water or heating till I get payed next...
  18. G

    Gw fulesaver f35

    I hAve a glowworm fuelsaver f35, It's been working good using my hive thermostat. Lastnight I put hotwater on ,but no hotwater, I checked boiler and the pump runs,fan runs but no pilot light . So I took bottom off and the red ignition button just pushes up so that tells me that it wasn't a...
  19. G

    fitted oven (s) breaker box

    Hi. Im going to get the correct wylex mcb and a megger and voltage tester. Its only for that one circuit.
  20. G

    fitted oven (s) breaker box

    hi ban I am listning to whats being said. You have helped me with things in the past and your info is always Thanked for. I havent decided what to do. All I was going to do was add a 32mcb . Not touch the main breaker. The cable and ovens was installed by a spark that works at my work (hes...