Search results

  1. V

    Hole in plastic soil stack

    If its just a tiny hole how about adralite...it'll be stronger than solvent weld offcuts. Vinny
  2. V

    soil pipe - need for venting?

    The old bathroom's soil pipe...is that vented? Does the new bathrooms soil pipe join into the existing soil stack and if so whats the distance between the two?
  3. V

    Which wireless roomstat?

    Cheers, I'll look at the Drayton controls, hoping to take ACS mid Jan....just need to get my head in my books get myself up to speed!! Thanks again Vinny
  4. V

    soil pipe - need for venting?

    Ok, the new bathroom..... Is this a second bathroom? If so is the soil pipe connecting into an existing soil stack? Pic/diagram may help. Vinny
  5. V

    Which wireless roomstat?

    Could somebody recommend me a wireless roomstat? I currently have a Glowworm Spacesaver 50, open vent system on a Y Plan, Danfoss 102e5 timer, at the moment there is no roomstat...I would like to add one to the system. I am considering the Honeywell wireless roomstat....are there any...
  6. V

    Twyford Cistern Linkage Leak

    The leak and black mess sounds like its the doughnut thats sits between cistern and pan. It needs replacing. It will leak more when the W/c is flushed. Vinny
  7. V

    breakdown invoice

    You could just make out your own invoice for fault diagnostics, whenever I get a call I always give the customer a price for fault diagnostics and advise them they will get a reduced rate if I carry out the work.
  8. V

    Radiator quickie

    Yes you can tee into the heating circuit BUT as its 8mm pipe I would be tempted to drain off the ch system and solder the pipework as 8mm is so small and the pipe is soft you have a bigger chance of the joint leaking if overtightened on a compression fitting....maybe going to either 10mm/15mm...
  9. V

    Mira Excel Fixed Showerhead leak

    Hi, I wonder if any of the plumbers out there can help me, I have a customer who has a Mira Excel shower with a fixed head that is leaking. When the shower is turned on the head seems to have to little sprays towards the ceiling. They say they had somebody out a few years ago when they...
  10. V

    Seimens RWB7 Timer wired incorrectly

    yeah i see what you mean now, just looking at ther wiring diagram. Thanks for your help namsag
  11. V

    Seimens RWB7 Timer wired incorrectly

    Cheers namsag, i can see the roomstat has 2 terminals connected, yellow to terminal 1 and red to terminal 3, i take it these these terminals need to be linked together. Only prob is my timer is in the kitchen and the cables from terminal 2/4 are terminated upstairs in the airing cupboard...
  12. V

    Seimens RWB7 Timer wired incorrectly

    not too sure what motorised valves, all I can tell you its a baxi 105e combi....if thats any help.
  13. V

    Seimens RWB7 Timer wired incorrectly

    Having probs with this timer, CH only works by control of roomstat making the timer useless. Had a look at it earlier, I can see the connections to it, as follows; Live Neutral & a cable connected to '2' and '4', I chased the cables connected to '2' and '4' back, when I found the end...
  14. V

    Strange sized WC inlet connector

    When I fitted one it wasn't in the box, my customer went back to Bathstore where they handed one to him....maybe worth a try.
  15. V

    Strange sized WC inlet connector

    Usually the hole for the water inlet is smaller than the standard 1/2", it just won't fit.
  16. V

    Strange sized WC inlet connector

    Where did you buy the WC from? I've fitted one for a customer who bought their WC from Bathstore, you should have an adapter that converts the 3/8" to 1/2". Its usually a plastic fitting.
  17. V

    Faulty timer?? or incorrectly wired??

    cheers namsag, i'll have a look.
  18. V

    Faulty timer?? or incorrectly wired??

    The timer was brand new along with the boiler and roomstat, the house was only built 3 years ago. This was a new installation, the worrying thing js the house belonged to one of the builders.
  19. V

    Faulty timer?? or incorrectly wired??

    I have had probs with my heating ever since I moved into my house about 4 months ago, Gotta Baxi 105e, Seimens RWB7 timer and seimens room stat. Everytime the timer comes on I have to turn the room stat up for the heating to kick in....which I understand the roomstat is doing its job...
  20. V

    Baxi 105e Heating problem

    yeah I can see a connection block when I remove the blanking plate. Will the baxi clock overide the seimens timer i have in thee kitchen or do i just remove it off its connection plate? thanks in advance Vinny