  1. P

    Rocks1 Apology I think

    Hiya, i phoned hotpoint today and told them that i had found the fault with the hot water valve as i was fed up waiting for them to call me as they thought the main pcb was faulty. they said the pcb is faulty and will take about 2 weeks, i explained that i have tracked it to the valve and...
  2. P

    Rocks1 Apology I think

    I recently was having trouble with my Hotpoint WD420, rocks1 suggested the hot valve. me being not very technical, called out hotpoint, they suggested main PCB failed. I am still waiting for hotpoint to come back. I decided to take off the top of my machine and poke around, and hay presto...
  3. P

    Hotpoint WD420 fault

    This is very interesting to read, as you may have seen from other posts i have been having problems with my Wd420, hotpoint are waiting for a new PCB, however, i may dig around and have a look at this capacitor. Pte
  4. P

    hotpoint WD420 washer dryer

    Hi Rocks, thanks for your help, Mr Hotpoint came out yesterday and said the main PCB was faulty so now wait 5 days for another one. Will keep you posted Peter
  5. P

    hotpoint WD420 washer dryer

    thank you, yes it only takes one lot of water in and then freezes. i will check the valves. is it normal for the drum to do 1/2 turn then stop, as sometimes it does this for a few mins before seeming to run normally?
  6. P

    hotpoint WD420 washer dryer

    Hi all, my hotpoint thingy has developed a weird fault, on starting it takes a little water in and then stops, sometimes the drum will turn 1/4 turn then stop, then go the other way after a couple of minutes, it has the door locked and wash light on, then it just seems to freeze, any ideas...
  7. P

    Radiator & gas bill

    £341 per month? I own a 3 screen 1000 seat cinema and our gas bill is £190 per month.
  8. P

    buzzing noise from flourescent ceiling light

    it will be the choke as they age the laminations loosen and vibrate
  9. P

    1000ltrs of oil in 2 months???????????

    not that it helps, but i get through approx 800ltrs per week, but then i run a cinema with a 250kw boiler
  10. P

    SWA to Air Source Heat Pump

    i am assuming that 8kw is the output, therefore its input would be around 3kw maximum, 4mm or 6mm would be fine, 2.5mm would be pushing it a little, you wouldnt need a 63a isolator, 25a would be fine
  11. P

    Help!! Trouble fitting strip light in garage

    the choke / ballast has gone short cicuit, throw the fitting away and get a new one
  12. P

    Fluorescent light ballast/choke rating.

    if they are 18/20w lamps you can run them in series, but you woud need a 40w choke and series starters. you could get a 2x 18w hf ballast which would run both lamps for about £20
  13. P

    Anti Freeze in heating system?

    Hi, I have a commerical heating system, not sure of capacity, but we have a potterton NXR3/37 boiler (210kw), we have had issues with pumping over which we have sorted (speed controller added to pump) We are in the process of de-sludging our radiators and it was suggested we put anti freeze in...
  14. P

    fuse down Air con unit

    although no help really, a lot of the IMI units i used to fit had a fuse in the condenser which was normally 3amp which protected the crankcase heater, fans and evaporator.
  15. P

    Trianco Redfyre Centrajet 13/17 - Just stopped working :(

    if its locking out, very unlikely to be your valves etc. more like you have run out of oil, or oil pump failure
  16. P

    no seals on cutout

    do not worry about it, as long as the meter seals are intact. :D
  17. P

    Help for sign light

    this may be a dim question, but why did you remove it? to me it looks like something to do with neon (cold cathode) but not quite sure what. What other control gear is there? pte
  18. P

    magic eye on oil burner??

    the magic eye is a photo electric cell which is used for flame supervison, i am not sure about this burner but most if not all have them, as the detect flame failure, if yours is dirty, it may not be "seeing" the flame and thus locks out, alos if they move they can cause problems, I wouldnt be...
  19. P

    potterton flexible pipe kit

    Hiya, I am looking for a flexible pipe kit part number 242262, i have searched the internet etc, but cannot find anyone with one in stock. Would any of you guys have one? Many thanks Peter
  20. P

    Potterton Kingfisher Flue

    I have a Kingfisher MFL50 floorstanding boiler and i would like to replace the vertical flue pipe which connects the boiler to the flue liner in the chimney about 2 foot above the boiler, and suggestions on a suitable pipe? I would ideally like white as the one at present is painted and now...