  1. M

    Borrowing a live

    Just to play devil's advocate and further my own understanding, presumably there is nothing wrong from a wiring perspective with say a programmer being on one circuit and a thermostat being on another? Each device would be powered by the live on that circuit and returned to the consumer unit...
  2. M

    Borrowing a live

  3. M

    Several sockets and lights on a spur?

    Hello All 2.5mm ring is protected by a 32a rcbo in the main consumer unit. I'm thinking about using a short length of 4mm to spur from a socket into the garage which is on the other side of the wall. This would feed a small "garage" consumer unit with a (I think pointless from a protection...
  4. M

    Can I used a vented cylinder stat with 24V?

    I've got a 240v Drayton HTS3 cylinder stat which I think is designed to work with 240v. My question is can I use it with a 24V low voltage common or does the stat itself need 240v in order to operate ? If I can't use it are there any alternative other than external relay ?
  5. M

    Boiler running without pump dangerous ?

    Thanks all - good variety of comments. The flow switch is something I hadn't thought of so in theory you could cap off the flow and return at the boiler and it just wouldn't start. Not that I recommended trying that test at home..... I maybe be in a situation where I'm relying on a motorised...
  6. M

    Boiler running without pump dangerous ?

    I have a feeling I'm asking for too much for this to be answered without a "why are you asking?" but here goes my 2 questions just in case anyone is kind enough to constructively reply. 1/ I have a Heat Only boiler on an S-Plan. If the external pump failed would the boiler just run for a bit...
  7. M

    Intergas, Opentherm and Nest

    Appreciate this is some time ago but definitely applies to today. I've just got my head around X-Plan and was thinking of doing that albeit with a relay+NC valve instead of shelling out £120 on a 28mm NO. Then I read this. Right in post 1, the OP says that "The heating functions perfectly -...
  8. M

    Honeywell MV Actuator Compatibility

    Not doubting you at all but given the NO valve is £120 (!!) need to be sure. Was that from their tech support telephone or tech support datasheets I could look at myself?
  9. M

    Honeywell MV Actuator Compatibility

    Hello All The last thread I can find about this is from 2004 and there was no conclusion. I have a V4043H on some 28mm pipe. Can I buy a 22mm V4043B1257 (i.e. normally open valve) like this one www.ebay.co.uk/itm/235808292122 take the head off and fit it to my existing one ?
  10. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    Your combination of trades is the best possible IMO - will encourage my son to do something like that if he shows interest. Hmm a new 28mm NO valve would be about £115. Might be easier to fit something like this to reverse the NO/NC signal. Don't think its a safety critical issue as no valves...
  11. M

    Intergas X-plan with two zones

    Just found this MNW67 - I know its a couple of years ago but what did you do in the end? Which controller? Do you know if the nest will send signals on both OT and SL ?
  12. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    Very interesting thanks - does appear to be a solution. Only issue is we have 2 heating zones. The second one is for just two rooms with its own controller and isn't used that often. Maybe I could leave that MV as a NC type and leave that zone as non-OT. If that called for demand I guess the...
  13. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    I'm definitely warming to the idea (so to speak) but the problem I have is my system is an S-Plan. So I would need the controller to open the MVs over 240v AND then talk Opentherm over the twin data cables. I've read that some people have done this but not convinced as I think it would need the...
  14. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    Not simultaneously obviously but for example if your heating is on and has reached steady state and then your controller suddenly wants to heat up the HW then it should instruct the boiler to go to max temperature and when finished revert back to opentherm (or in your case the Valliant system...
  15. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    Lots of old threads and questions about opentherm on an S-plan. Anyone know if any of the controllers solve the issues? i.e. open the respective MVs then allow opentherm to take over when its heating? HW to take priority and run at max temp etc ?
  16. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    A couple of interesting replies - thanks. What controller are you both using ? I started looking into EPH and liked what I saw. The main down point seems to be cosmetic - it looks crap. Nest v3 is another option I suppose. It seems there aren't many....
  17. M

    How can I connect this rad up?!

    Wouldn't even think about bending the legs without a spring.
  18. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    I'm not missing that point as yes that's the entire idea isn't it? Maybe I'm guilty of not restating that fact in my post. As you say that's the entire idea. I leapt forward and asked what problem does it solve? None of this explains how and why OT AND WC (or load compensation AND weather...
  19. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    I look forward to your explanation as to why you think WC and OT work well together......
  20. M

    Opentherm Weather Comp and Intergas HRE 24 OV

    I haven't seen much information about exactly how and why you'd want either or both of these. I suspect those that don't know just say "...the boiler will use the WC and OT to work more efficiently..". Yeah but how ? What problem are we solving? Lets deal with that first. So its said that with...