Search results

  1. R

    adding two downlighters and pendant light to one light already in the room.

    evening all, next job on my list is adding two downlighters and another pendant light to a bedroom which already has one central light all controlled by one switch. I've bought some 4 terminal 20a junction boxes. I've run the cables from the downlighters and the additional pendant light so...
  2. R

    30a connector block, how can I tell

    no, they want them open (madness) as she is a teenager and its going to be aright mess but they want them open :)
  3. R

    30a connector block, how can I tell

    thanks all, glad i asked now. so perhaps having a debate now with the wife and telling her i will need the mirror to go as far as the skirting board. so if thats the best method for me, take skirting off after they have measured up for the mirror and then put a drywall box underneath the...
  4. R

    30a connector block, how can I tell

    unfortunately its going from floor to ceiling.
  5. R

    30a connector block, how can I tell

    if ive read correctly the wago 222 series is classed as MF https://www.amazon.co.uk/Wago-compact-terminal-connector-blocks/dp/B0070UP17K/ref=sr_1_22?crid=F595ZELNF4R1&dchild=1&keywords=wago+222+connectors&qid=1620081324&sprefix=wago+222%2Caps%2C158&sr=8-22
  6. R

    30a connector block, how can I tell

    is there something else which you can recommend that would work? thanks
  7. R

    30a connector block, how can I tell

    great thankyou, i'll get some ordered from amazon... would they just sit loose in the drywall box then? these connectors...
  8. R

    30a connector block, how can I tell

    ive just put some pictures up, the original yellow and green earth is there (when i took the original picture i hadnt put it in the connection block) when you say maintenance free connectors are those the wago type connectors
  9. R

    30a connector block, how can I tell

    Here's how I have left the connection at the moment
  10. R

    30a connector block, how can I tell

    ok thanks, can i use a drywall double box that was in the space originally? like your idea about plastic and cutting it so it fits inside the box.
  11. R

    30a connector block, how can I tell

    Took a couple more picturew the mirror will be wardrobe to wardrobe
  12. R

    30a connector block, how can I tell

    the mirror is going to be floor to ceiling and span the whole.
  13. R

    30a connector block, how can I tell

    hi, yeah it will, the mirror company will stick the mirror to the wall. i cant lift the flooring it to move it over either. hmmm this is what i was worried about
  14. R

    30a connector block, how can I tell

    I've had a go today, mirror company coming in a tomorrow or Wednesday. Pretty much up to where I am with it. I've got the socket and drywall box in and fitted and just need to connect up the wiring (spur) with the old double socket. Question for the experienced people , can I leave the...
  15. R

    30a connector block, how can I tell

    Hi all, I'm blanking off a double socket and a mirror is going over it. I'm spuring off the double about 12inches along the wall . I will order a 30a from Wickes in another order I have. I have this big connector block but how can you tell I would have thought it would be written on it.
  16. R

    How can i re position this double socket?

    bad photo shop, but something like this is what the wardrobe will look like
  17. R

    How can i re position this double socket?

    thanks, all yeah not sure if i did a good enough example of explaining what i planned, but yeah spur off from the original double as the end of the wardrobe will be against that wall, it will be fixed to the wall but its a double ikea pax wardrobe I cant lift the floorboards or the flooring on...
  18. R

    How can i re position this double socket?

    evening all, Im going to put a double wardrobe where the socket currently is so i need to place it more central (where ive circled) so i can put the wardrobe there. bear with me here, can i spur off the socket that is there, chase a new socket in the place i need it and blank off the...
  19. R

    Scantronic 9651, is there a way to turn volume down on countdown on part b setting

    evening, tried the manual and i cant see where or even if its a thing. when the alarm is on part set B, which is upstairs off and downstairs on, when i come down in the morning the countdown beeper is quite loud, I get up quite early for work and kids are always saying i wake them up when...
  20. R

    Neff built in oven light not working, changed bulb and still not working

    evening all, Neff want £90 for a call out to look at the oven, we have survived for several years like this but it could be a simple fix. The light stopped working, there is a glass cover at the top of the oven, ive changed the bulb and ive checked that prongs inside the fitting are out...
Back
Top