Search results

  1. G

    "Gas" in Radiators

    Thanks, and yes valid point, I did that 2 years ago, however the water in the whole system was pretty black this time.
  2. G

    "Gas" in Radiators

    Thanks, I'll run it for a couple of weeks then check water.
  3. G

    "Gas" in Radiators

    Good advice thanks SGM. Well I did the bottle trick with the gas out the radiator, which I'd left over night & it did "pop", so i think it's quite conclusive that it's a build up of Hydrogen gas overnight due to excessive corrosion products in the water/radiators. I've drained & flushed the...
  4. G

    "Gas" in Radiators

    Thanks, I captured some of the gas in an old beer bottle when bleeding this afternoon, and there was a definate "whoosh" (not a pop) when I stuck a long lighter into the neck. I'm going to do it again tomorrow just to be sure. Ps; yes, I've bled the pump too. If the gas ignites or pops...
  5. G

    "Gas" in Radiators

    Deary me, I've no idea why posts in this section gets so animated & people getting uptight & angry. It's supposed to be a help forum. I only popped on to get some advice, not to start another flame war on here. I'm quite comfortable using the term gas, and as a charted engineer, (in case you...
  6. G

    "Gas" in Radiators

    At last a helpful reply. Much appreciated, I'll do that tomorrow. Thank you.
  7. G

    "Gas" in Radiators

    I dont, and I've purposely used the term gas, as air is also a "gas".
  8. G

    "Gas" in Radiators

    Some advice please; I've a Potterton Promax Fsb boiler and an open vented system which is suffering from excessive gas in 2 towel radiators. I've established that the system needs drained, flushed & refilled with inhibitor, as the Magnaclean filter was quite heavily contaminated with black...
  9. G

    Vokera excell 80sp Advice

    Thank you, we have our uses. :-)
  10. G

    Vokera excell 80sp Advice

    Thought I'd update the outcome for other "DIYrs" who may happen upon this thread; Whipped the DHW microswitch off, stuck a meter on it, was only operating intermittently, popped into my local heating spares shop, and bought new one. 15 minutes to stick it on & reconfigure case etc, now working...
  11. G

    Vokera excell 80sp Advice

    OK thanks, I guess a chartered mechanical and electrical engineer won't be able to understand. But thanks for the advice.....
  12. G

    Vokera excell 80sp Advice

    Old vokera is going to be replaced in the spring, therefore trying to keep it alive until weather and cash permits. The problem; The hot water side failed completely, freezing cold all the time, so having researched the forum, looks like the diverter valve gubbins would be prime suspect. I've...