  1. Madrab

    New pressure reducing valve

    yes - usually are IME.
  2. Madrab

    Kitchen sink pull down spray taps

    Taking the regs into account then it would really be a double check valve, if the spout can reach down into the water in the sink and that water could contain cleaning/disinfecting agents (CAT3).
  3. Madrab

    Cleaning silicone mastic

    Nope - not come across anything that will remove water staining from silicone. If normal soap and water and a soft nail brush won't lift it then it's cut out and replace I'm afraid.
  4. Madrab

    Expansion vessel unvented cylinder

    Totally agree @Johntheo5 - and one of the most common mistakes is the EV vessel either being left at it's factory pre-charge on install or re-filled to the level that's marked on the side without though to the actual system pressure. That can then sometimes create issues with...
  5. Madrab

    Expansion vessel unvented cylinder

    As long as you can get the connector from the pump to the top of it then it should be able to be done in situ, I have a stirrup type pump that has a 3m hose on it for exactly that kind of thing. if not then it's a drain down and remove. Don't forget to balance out the pre-charge to the mains...
  6. Madrab

    Expansion vessel unvented cylinder

    Nope - dead quick and easy to re-pressurise with the correct type of pump, though if it is a remote EV (not an in cylinder baffle type) then it should really be done at service time by a qualified Unvented chap.
  7. Madrab

    Shower Waste Part needed

    Never take a chance, the nut should happily screw onto the fitting to at least 1/2 of the thread depth. If the rubber seal doesn't fit into the nut when the it's on the end of the flexi then get a little silicone grease or soap and coat the rubber seal and spigot end and then put it all back...
  8. Madrab

    Scalding water with Hive

    As per the 2010 revised regs - all new builds or new baths in existing should have TMV2 mixing valves fitted to baths, regardless of tap types.
  9. Madrab

    Hot water supply to shower and kitchen luke warm. Temporarily no cold supply.

    If the water coming out of the boiler is as hot as it should be and at least one outlet is getting that temp of hot water and there is no cold feed to the shower then there's no way for the water exiting the shower to be cooled down. Therefore there has to be a cold water crossflow and it's...
  10. Madrab

    Shower Waste Part needed

    That compression end of the trap should be a universal 40mm. How are you trying to fit it? Take plastic nut off the fitting and then the washer and black rubber fluted seal. Put the nut on the spigot end of the flexi, then the plastic washer and then the black seal, with the fluted end...
  11. Madrab

    Scalding water with Hive

    If the cylinder stat is set to 60deg and the system temp is > 60deg then depending on the travel distance to the tap and the insulation of the HW pipework, then HW should reach 60deg in the cylinder and then arriving at the tap @ ~55deg, would be spot on. If there are no blending (TMV) valves...
  12. Madrab

    Hot water supply to shower and kitchen luke warm. Temporarily no cold supply.

    Is the kitchen sink a mixer? Basin separate taps? It's possible there is cold water crossflow happening as the shower hot feed is no longer balanced. I would suspect that re-instating the cold feed to the shower may sort it out.
  13. Madrab

    play / tolerance in 110mm waste fittings - tweak gradient possible?

    I always try to get as close to ~ 40-45mm/m (1:25) as possible as I've found that's the sweet spot for a self cleaning run. They state 18mm is the min but that would have be written with 6/9L flushes in mind I would think. Not sure if they've ever revisited that figure TBH I would always work...
  14. Madrab

    Shower Waste Part needed

    Can I suggest that you really try to avoid using a flexi pipe on a shower waste. They are know to cause all sorts of problems further down the line with sagging and restrictions.
  15. Madrab

    Immersion cut-out with a twist

    Earth continuity been checked? As suggested, an experienced electrician should be able to fault find. How is the immersion powered? Does it have it's own radial circuit from the CU or is it a spur from the Ring?
  16. Madrab

    Changing mixer shower and tap

    You want to take the controls and the plate off of the shower to see what's behind, depending on what access there is will determine what needs to be done. As suggested - tap off the basin is straightforward.
  17. Madrab

    Re sealing a bath

    Just need to ensure the new will take to the old - use a solvent cleaner - IPA - Meths - White spirit etc before applying.
  18. Madrab

    Re sealing a bath

    Are you talking about the silicone that runs in the corner vertically up the tiles? Sometimes best to cut the first 500mm and renew so the transition is all the same new silicone. Would really comes down to condition but TBH for all it is, it would be just as easy to do it all in a oner.
  19. Madrab

    play / tolerance in 110mm waste fittings - tweak gradient possible?

    As long as it stays within the min fall requirements - 18mm/m fall then it would be fine. Though if I gauge it correctly 1:60 is slightly below that? Worth noting though that 18mm is the min per the regs and not necessarily the best when it comes to a pipe run being free draining and self...
  20. Madrab

    How to best relocate this waste pipe?

    Is it a push fit coupler that's on the pipe with the blanking plug in it?