  1. L

    Bi folding doors instillation

    I could do with some help, we got a company to install some bi folding doors in my mothers house paid 25% deposit upfront, they then messed her around before the instillation saying they would install the windows on a certain date, to then cancel saying there was problems with the...
  2. L

    PFC question for 2391 exam

    im gonna need alot of luck! i know my terminology will let me down! thanks for the input, i have to be there for 6 so prob will start at 6.30!
  3. L

    PFC question for 2391 exam

    dont think im ready for the exam myself, its tomorow at 6 (not sure how u know roughly :) ), though i will give it my best! think a break has helped been at it since 7. if the lowest protective device has a breaking capacity higher than the PSC at the origin then you dont have to take...
  4. L

    PFC question for 2391 exam

    still none the wiser! last sentance on 54 before 2.2.17 phase sequence is this where the protective devices used at the origin have the necessary rated breaking capacity and devices with similar breaking capacity are used throughout the instillation, it can be assumed that the regulations are...
  5. L

    PFC question for 2391 exam

    doing revision for 2391 exam and i cant seem to find the answer to a question, would appriciate any help, i may just be missing the obvious here. :x state under what circumstances is it unnecessary to carry out a prospective fault current test at each sub-main distribution board on a...
  6. L

    Condensation in loft - Damp issue? or sumthing else?

    I went up before, some of the insulation was covering the crossflow ventilator (Plastic things :P ) at the top and even some were blocked at the bottom as some had been rammed that far down it went into the eaves touching the soffit vent. not all though, some were okay, one had that much forced...
  7. L

    Condensation in loft - Damp issue? or sumthing else?

    Okay thank you for that, ill go back up again make sure both sides arent blocked and ill put the spare insulation back down but not close to the ends so im not blocking any ventilation, as far as im aware there is no harm in having two layers of insulation Ill make sure we use the extractors...
  8. L

    Condensation in loft - Damp issue? or sumthing else?

    now in the very corners there is small peices of insulation stuffed in. is it mean to be like this, in this pic you can see the middle one i have removed. So on one side of the loft i have removed the double layer and removed the insulation in the very corners, is this how it is meant to...
  9. L

    Condensation in loft - Damp issue? or sumthing else?

    okay ive been into the loft the roof timbers do look wet in the pics but it doesnt seem that bad when i had a look they are slightly wet were there touching the roof felt as i would expect with all the condensation on the felt. im not sure what you mean by the eaves. The loft has wooden...
  10. L

    Condensation in loft - Damp issue? or sumthing else?

    Mrs is home in a few hours so she can look after the daughter then im gonna go into the loft and take a look and check ventilation, i thought the same about the roof timbers when i looked at the picture again so ill check.
  11. L

    Condensation in loft - Damp issue? or sumthing else?

    Okay done a bit of searching and this looks like condensation. Now things i dont think are helping. My mrs washing clothes and having loads of wet clothes on the radiators! This a difficult one to solve the kitchen small and there is no room for tumble dyier, im thinking of putting a...
  12. L

    Condensation in loft - Damp issue? or sumthing else?

    okay I moved into my first house about 2 years ago now, and the house is a small 2 bedroom semi detached 11 years old, last winter when I went into the loft I noticed water droplets all over the loft roof and didn't really think anything off it and I'm sure I went up in the summer there was no...
  13. L

    30 amp rewirable fuse feeding radial with 4mm cable

    ty, sorry bad terminology on my part, spur of a spur i should have said
  14. L

    30 amp rewirable fuse feeding radial with 4mm cable

    possible to spur of this and im guessing u would have to spur off using 4mm cable, is there a limit on spurs? can u spur 2 sockets in series off a socket.
  15. L

    help needed and soonish :)

    hey people, Ive got my c&g 2391 test and inspection exam at 1 today, im all ready to go except im confusses about one thing. Continuity of ring final circuit condutors When carrying out step 3 which is connecting the live (line) and the cpcs together on a ring main to carry out the figure...
  16. L

    Running cable under tiled floor?

    Is it allowed to run cable under a tiled floor?if so what are the options on protecting the cable, A kitchen has a work unit in the center of the kitchen and a spur off the ring is needed in the unit to run a small fridge, other than running it down some sort of pole from the roof to the unit...
  17. L

    Price of a new combi boiler?

    well my combi boiler was condemed previously a vokera linea 24, and just started to get quotes, anyways got british gas out first and they quoted me 3k!!. cheapest 1.5k which is a whouster 24 like? spelling prob wrong lol.
  18. L

    linea 24

    still waiting for sum one to come see my boiler, anyways pressure loss is one of my problems, boiler been off a few bays now, i put 1 bar in to see if i lost it, if i had aleak but couldnt see it. would i lose this pressure even though the boiler hasnt been running. if anything i seem to be...
  19. L

    Pressure gauge faulty?

    currently awaiting sumone to come out to see my boiler which is looking like friday! anyways just though id put this question across? the boiler being a volkera linea 24, i have problems with pressure loss, still not sure whats the cause, now i was loosing pressure over a few days from what i...