Search results

  1. D

    IDEAL ICOS HE18 - Firing problem ...help..

    Every cloud has a silver lining. I quite like this boiler.
  2. D

    Ideal ICOS HE 18

    What is this similar experience Knowing what is involved in replacing this PCB, I am surprised a Gas engineer would suggest you replace the PCB especially the nature of the lockout.
  3. D

    Ideal ICOS HE 18

    I as a Gas Safe engineer would never say to end user to do this, that or the other
  4. D

    Best / easiest washing machine waste to sewer connection

    I think north of the border it does. Left CI is rainwater, right,o soil pipe
  5. D

    Why is Trump so keen on Putin

    I thought India too.
  6. D

    Switch to a combi boiler

    Was the gas pipe gas meter to boiler replaced or size of pipe checked that gas delivery is as it should be? If the gas pipe to boiler is undersized, often when the gas hob ( if you have one) is running, observe size of hob flame, then run a hot tap. Hob flame will diminish in size. It is not...
  7. D

    Can Unvented Cylinder improve mains flow rate on 2 simultaneous showers?

    If both showers pipe run have same flow resistance to water flow then boiler hot water flow will be divided equally if both showers were run at same rate if that makes sense
  8. D

    Boiler help/advice

    Isolation valves. Recently had to isolate said valves under my Vaillant Ecotec plus 832 to remove a radiator from the system. Used Allen key to turn the spindle quarter turn with some difficulty. After the radiator was drained and removed, pipes capped, when I returned to the boiler, pressure...
  9. D

    yet another boiler losing pressure thread

    Do a search, you will find plenty on that topic
  10. D

    Potteerton boiler

    Potteerton. Not heard of this brand
  11. D

    Method or madness in this CH installation?

    I suspect boiler is a Vokera Maxin 24 or 28. It does. Is fitted in the diverter valve My suspicion is the boiler lacks proper system balance and if there is no room thermostat, installation will benefit if one was added. Certain parts may be difficult to get though some parts are Vokera items...
  12. D

    Trump v Zelenskyy

    Bone spurs trump
  13. D

    Musk on drugs

    Wonder why then the MODS said abusive post removed or did I misread.
  14. D

    Musk on drugs

    Top of your post says abusive post removed. Public forum, why the abuse.
  15. D

    Has wrong kW rated boiler been fitted

    Do you know combi boiler operation? I would love to see a combi provide 60 degrees of hot water at stipulated flow rate let alone 70 And where does legionella come in, this is a combination boiler that heats water you drink- no stored water here A combi will heat cold water by35 degrees a flow...
  16. D

    DOGE gets kicked in the nuts

  17. D

    Any truth in this msnbc clip?

  18. D

    Ideal C35 Running Cost

    C35 is a 35 kW combi boiler. When running a hot tap, it will fire at 35 kW and then modulate to maintain temperature. For heating multiply each radiator by 1.5 to guesstimate the load on the boiler- doubt it will come to 18kW even. Do you have a room thermostat or relying on TRVs to regulate...
  19. D

    Imperial radiator size (690mm) with new rads

    I have always believed women can do the same job as men, sometimes better so question for you is, how do you intent tackling this task You are going to have to fit the new radiator such that the valve tails line up with the existing pipe. Double panel will cause problems if pipes have no...
Back
Top