Search results

  1. B

    Help! New central heating system blows timeswitch every time

    It is a Danfoss RMT230 - the one with 4 terminals http://media.photobucket.com/image/rmt230/johnp68/rmt230.jpg On the diagram it says T6360B which is a Honeywell with 3 terminals - could this be the problem? I can't remember offhand which terminal went where, hopefully I haven't sent a...
  2. B

    Help! New central heating system blows timeswitch every time

    Hiya any help would be appreciated. I have just installed (electrically) a central heating system (Y-plan) and when I press the boost button on the timeswitch to get power to the boiler, it blows the timeswitch and trips off the circuit breaker in the DB. I have double and triple checked that...
  3. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Right ok that's the motor sorted for me then, cheers. Anyone know how to wire a ringmain? :wink:
  4. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Sorry that im not as experienced as you with this type of thing - i can see where the live and neutral come in, and how to get the circuit going around incorporating the seperate controllers, i just honestly can't see where to bring the motor connections out of it and to the motor. I know...
  5. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Ok then so the connections for the motor will come from 96 and 95, sending the two browns into the junction box (I think that's what you meant) - is there another brown to come from somewhere? I wish I could've afforded to go on the AM2 training course thing - never done a motor or MICC in work.
  6. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    I'm sorry if this sounds slightly retarded, but I'm a housebasher and this is all new to me. I've gotten my head around it pretty much, I can see why the current will flow through the red neon and straight to neutral if its off, and I can see where everything will be going, but I can't see where...
  7. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Thanks Coljack. Is the Hold on simply a link between 63 and 64? And is a link required between 97 and 98 or is it just switched across?
  8. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Cheers for the help so far guys, I take it the TP&N s/fuse will need 2.5 singles going to the industrial socket?
  9. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    I have to build the remote control station (start inch stop) from scratch but the motor starter already has its links in.
  10. B

    PLEASE HELP - AM2 tomorrow and the motor is baffling me

    Hello electricians. I'm doing my AM2 tomorrow and the main thing that's bothering me is the motor. Here is the diagram: http://www.net-works.org.uk/figurec.asp http://www.net-works.org.uk/figureb.asp It's all wired in 1.5mm singles, just wondering if anyone could tell me if it's all got...
Back