  1. D

    Redland concrete plain black roof tile

    These tiles are they cheap and nasty or OK?
  2. D

    Identifying flow and return

    It's a ideal isar. I do not mean the outer case of the boilor. I mean the horizontal piece of kitchen cupboard.
  3. D

    Identifying flow and return

    Can take top piece of cabinet out to more easily install magna. Then put new top piece in as the piece is water damaged anyway of previous leaking drain off. This way if the partial block I have is on return which I suspect it is the magnaclense should catch it before going in boilor.
  4. D

    Identifying flow and return

    Found return by boilor with a spiro installed not very good for access.. Looking at shopping this spiro for any pro 2.
  5. D

    3/4 bsp hose connector - Spiro filter

    Does a 3/4 hose connector like one in image fit to end of a spiro filter drain off ?
  6. D

    Suspected blocked feed t on heat only system

    Thanks. Getting chemical in tonorrow. I suspect its on the return in blue on diagram.
  7. D

    Suspected blocked feed t on heat only system

    Vent pipe getting hot but no water coming out when there today. It did the other day though. So thinking its a partial blockage maybe ?
  8. D

    Suspected blocked feed t on heat only system

    The feed isc15mm from f .n e. Yes thete a separate 22 mm vent pipe over f n e.. Yes check copper t as much as could. It seems OK . I'm.going bang some sentinel x400 in. Can this go in and just run on hot water as the heating not on everyday.? Thanks
  9. D

    Suspected blocked feed t on heat only system

    When engineer fitted 3 port he told me the heat or hot water never worked. He never got in loft to bung tank so likely dropped the f n e pulling in air. He then backfilled the system from the drain off in picture. The banging was there prior. Do you think its possible sludge has been pushed out...
  10. D

    Suspected blocked feed t on heat only system

    Yes only since 3 port was changed.. It does appear to be hw problem I think. If it is blocked coil or restricted on return from cylinder this sounds very problematic. Can chemical clean it ?
  11. D

    Suspected blocked feed t on heat only system

    So I went today. Cleaned f n e out. Changed gate valve to a new ball vall. Replaced t and wet vax pipes. Water dropping from f n e no problem. The t was not that much blocked ( picture attached ). Upon turning hot water/ heating on the feed pipe got hot again but there no block. What else...
  12. D

    Identifying flow and return

    If I already have a spiro at boilor ( can hardly service its that tight) . This magna is mainly to dose and fit Magnaclense is it OK on flow ? Or would it just be batter dosing chemical from radiator and connecting magnaclense to radiator. ( although not as easy as to filter )
  13. D

    Identifying flow and return

    I think you may be right. The return is not visible in cylinder cupboard
  14. D

    Identifying flow and return

    There no more pipes apart from ones in image
  15. D

    Identifying flow and return

    There no room at the boilor the pipes are tight to the ceiling
  16. D

    Identifying flow and return

    Is this return ( In blue) 'm not up on identifying on heat only. Combi would not be a problem . Thanks
  17. D

    Suspected blocked feed t on heat only system

    Was going to just catch it with folding bucket and / wet vax. Do not really wanna drain out lower incase block although unlikely is elsewhere or don't get block out and has a nightmare for some reason back filling. Just feel more comfortable doing it this way .
  18. D

    Identifying flow and return

    First time fitting on a heat only system. Just want to be sure before start . Got no problem with bunging f n e and vent. Isolating water and wet vav ing the remainder water in pipe so no water when cut it. But I think I have got the flow and return arrows wrong way. Return is after pump going...
  19. D

    Suspected blocked feed t on heat only system

    Sorry for confusing. It's spinning free left and right stopping each way. Maybe partially blocked at T then water taking path of least resistance up the feed. I think I'll bung the tank. Isolate water to f n e. Then clean f n e. After that open the t conpression and check if blocked. Do you...
  20. D

    Suspected blocked feed t on heat only system

    I can remove the front box to get at gate valve. Few screws amd the full piece of ply comes of. I recently got a engineer to change 3 port valve. I think he may amd shut gate valve but unsure and maybe its stuck shut. Althoug the handle is spinning freely. Do you mean unlikely the gate valve...