Search results

  1. D

    32 mm compression on 35mm chrome

    I have re ordered solvent weld . To do it in that while floors up
  2. D

    Tile around freestanding bath waste

    Tiles are big. 1200mm x 600mm
  3. D

    32 mm compression on 35mm chrome

    Yes I'm going to put timber supports in and clips. I can change to conpression if better
  4. D

    32 mm compression on 35mm chrome

    Managed to get waste in. Question now is I know nor ideal but I had to use straight conpression to convert from crome to pladtic. . Then I used a push fit elbow to get out wall.. I could change the pushfi elbow to conpression. But would you feel OK having these connection under floor. ? If...
  5. D

    Tile around freestanding bath waste

    Yes bath can be removed and a hole cutter for tile but the crome pipe is a bend in one. Would I be able to slide tile over crome and around the bend ?
  6. D

    Tile around freestanding bath waste

    How would you best tile around this waste ?
  7. D

    32 mm compression on 35mm chrome

    If I rotate the trap 180. It clears a joist . However this goes above a cabinet in kitchen. In original position the ceiling is out in kitchen below bath so I was going to connect below. How do you connect above and leave for tiler if I rotate trap As if trap is connected the tiler cannot...
  8. D

    32 mm compression on 35mm chrome

    Or can I get a 32mm to 40mm conpression elbow to move horizontal abit and just take a notch out joist for compression fitting to sit in ?
  9. D

    32 mm compression on 35mm chrome

    Got a another problem now. I got the 32 mm to 40mm conpression on amd drilled hole through plyboard for trap . Hit a joist and cannot move bath left or right due to space. Lucky ceiling is out below but I do not really want tp hack loads of the joist. Can anyone advise if they think OK to use...
  10. D

    32 mm compression on 35mm chrome

    Hi Yes I took Stanley to the 32mm nut yesterday and got it on . Thanks
  11. D

    32 mm compression on 35mm chrome

    Either end of compression won't get onto the 35mm crome. 32mm side or 40mm side. 32mm nut won't even get over the crome
  12. D

    Trap connection problem

    Anyone know best way to get from 35mm crome to 40mm plastic Just tried a 32mm compression on one end and 40mm on other and either side will go on 35mm crome. I have seen a crome to 32mm connector online but not crome to 40mm. Picture below a compression fitting which will not fit .
  13. D

    32 mm compression on 35mm chrome

    Will 32mm compression fit onto 35mm chrome pipe ?
  14. D

    Trap connection problem

    Would one of these work ?
  15. D

    Trap connection problem

    I have a crome bath waste and have been trying to connect a 40mm hepvo waste trap to it but it's way to big. Tried a 32m which could not go on. I measure the crome end and it's 35mm. How do I get a trap to connect to this secure ?
  16. D

    Shower and batb waste

    If got a shower and bath in. And waste needs re doing out wall into grid. Is it better to have shower and bath on separate runs into a hopper ?
  17. D

    Wall tiles on bath platform

    Will have to stand on platform to then get in bath
  18. D

    Wall tiles on bath platform

    We have selected a tile for round bath and would like the same tile for the area where bath is on a platform. Would it be OK to use the wall tile just on the bath platform.? They are only small tile like brick size
  19. D

    Isolation valve into flexi

    Is it OK to put a isolation valve directly into this end of flexi hose ?
  20. D

    Backerboard

    A platform has been built in my bathroom to put freestanding bath on. This platform has been plyboard with 18mm plyboard. Prior to tiling would it be best to cover the plyboard with backerboard. Thanks
Back
Top