  1. W

    Potterton Performa 28 aps or pcb?

    The three connections are common, normally open & normally closed. The pcb checks state of aps on demand & if it has stuck in closed position it will not allow fan to run
  2. W

    ideal Response 200 boiler low pressure problem

    If you are losing the pressure in 3/4 days then you have a leak. Check the blow off pipe which goes outside to see if it drips (especially when htg is hot) also check rad valves when cold (especially under plastic tops) if no joy then get a torch & crawl under floorboards to find it
  3. W

    poor hot water flow

    12l per min cold is pretty poor is there any valves that are partially closed or is all the street the same?
  4. W

    leaking vokera boiler

    If it is dripping when c/htg is on check pressure as it may be on 3 bar due to lack of air in expansion vessel
  5. W

    old valliant vcw t3w does not ignite.

    Is there any air in blr? There is a bleed nipple inside comb box but don't go in there as the rope seal is asbestos & they cover is tricky to fit back call some-one in
  6. W

    Ravenheat big problem! HELP!

    Very common problem on these is the pilot injector as there are 2 minute holes which are difficult to clean & are easily blocked so ign pcb never realises that pilot is actually lit
  7. W

    Potterton Promax Combi 33 HE Plus, water pressure too high

    When taps are turned off you will have the full dynamic pressure from the mains but a pressure reducing valve may help
  8. W

    Help choosing replacement boiler

    Does the flue go into your garden or a neighbours as pluming may be an issue. Why not call someone in to give you some quotes as blr may need to be moved
  9. W

    HW doesn't heat when CH pump on??

    As a temporary fix (if updating next year) have you got an immersion back up that you could use?
  10. W

    The pilot light has to be regularly ignited manually.

    Migh help if you posted what make & model etc
  11. W

    Fitting a Whitenight vented tumble dryer

    Am i right in thinking this is an electric tumble dryer & not a gas one
  12. W

    Jaguar Boiler problem

    Jaguars use a differential valve which is the same as vokera maxins so a maxin service kit is what you will need
  13. W

    Homecare & Boilermates

    Yes boilermates on 3 star are covered but not on blr & controls
  14. W

    Baxi Solo not igniting burner properly

    After pilot lights does it carry on sparking? If so there is a kit to change electrode & pilot assy or could be a duff pcb
  15. W

    Vokera linea 28 hot water issues

    Probably thermister, when you changed plate heat ex was there any black deposits on the 2 c/htg connections?
  16. W

    how dirty would a central heating system be after 2 months

    Could be flux residue to be on safe side add some sentinel x300 run until hot then drain all water, fill up & run till hot again then re-drain then on last fill add inhibiter like sentinel x100
  17. W

    * VAILLANT VCW 242 CH HEATING NOT WORKING!! PLEASE HELP *

    Make sure ALL of the impulse pipes are clear & change servo valve
  18. W

    Central Heating confusion LP522

    Could also be a defective end switch on diverter valve
  19. W

    Air in Central Heating

    Is it air or is it hydrogen?
  20. W

    Replacing a radiator - radiator valve tails

    Dont try to prize them out as they are screwed