  1. B

    Lead Gutters and pipework

    erm yes, its not ideal. Does it have to be replaced, I'm sure if your looking at adherence to local water bylaws for potable / drinkable water taht would be yes. Suggest this is moved to plumbing pages
  2. B

    Sowing a lawn

    Hi, I've just moved into a new house and am creating a new lawn to the front of the property. Help. Its block paved just now and its getting relocated to the back yard (see my other post!) Where do I start? Am I best to leave it until next yera? Whats the sowing vs buying grown...
  3. B

    What kind of wood/timber?

    Hi, I've just moved into a house from an apartment/flat after 11 years in relative containment - woo hoo, however i'm a garden novice My first question is thus; I'm creating a nice block paving area at the rear of the garden where the sun shines most frequently (naturally). However as I'm...
  4. B

    virgin hd freeview to pvr

    Can anyone confirm if its possible to take an output from my virgin freeview hd box (new last 2 weeks) and put through my ~2 year old Thomson PVR box in order that I record? The Thomson PVR is a Top Up TV 160GB version and appears to only have a RF input. There are 2 scarts, but I'm unclear...
  5. B

    aerial installation glasgow

    Hi What transmitter should I attempt to line my new digital terrestrial aerial up to from a house in the south side of Glasgow. And - does anyone know its longnitute/latitude or compass direction from Glasgow to pick this up (with just a compass!)
  6. B

    Approximate cost of a new slate roof

    Camster, I'm based in Glasgow and also keen on a new roof and have a similar profile roof so I'd be interested to hear you ultimately go with and the outcome.
  7. B

    DHW lack of temperature

    I've just moved in to a shiny new house (new for us that is, its and old property). The house has a 2001 Vokera Linea 28 combi central heating. The system appears to be working fully bar the temperature of the hot water flowing through the show head. The shower is over the bath and is I...
  8. B

    Glow worm boiler whistling noise

    and yes, pump on set on speed 3 and cannae take any more captain....
  9. B

    Glow worm boiler whistling noise

    thanks for your response... the last service looked at over gassing I think, however within a few months after service, noise returned. I'll call someone out. I'm not replacing tho as it seems it aint broke yet, plus I'm moving so the investment case for a few system is somewhat weak...
  10. B

    Glow worm boiler whistling noise

    so what is over gassing? and can this in any way be linked to temperature sensor failure or being out of calibration? e.g. if return water sensor is suspect, then will this over shoot? also, I've got what looks like an AAV at high level... perhaps I'll try replacing that in case its causing...
  11. B

    Glow worm boiler whistling noise

    Standard forum question perhaps, but here goes... I have a Glow worm Economy Plus 50FF. It is connected to a primatic DHW cylinder. I have 2 circuits each with a 2 port MV and a seperate pump (Grundfos UPS15/50). All pipework is in 8mm. When the boiler fires from cold, everything appears...
  12. B

    primatic cylinder

    erm hello... i started this for tehcnical help. instead I've got a few fools ranting on about nothing technical - just brilliant. why dont you all join the womens guild instead, im off to recommission the cylinder alone.
  13. B

    primatic cylinder

    ok, maybe system was not the right word Boiler is Glowworm Economy Plus 50FF - there is no expansion vessel in the boiler. I think a weblink to this, if not similar is this (although this says Glowworm Ultimate 50F)...
  14. B

    primatic cylinder

    Hello, I live in a tenement flat and have a Glowworm System boiler connected to a primatic DHW cylinder. My DHW is brown and I assume my air bubble has gone. So... I've drained the system and am awaiting a refill but before so, I wanted to see if someone could write a methodology on...
  15. B

    Wiring Xpelair DX400T centrifugal fan for internal kitchen

    thanks... as per the digaram I presume
  16. B

    Wiring Xpelair DX400T centrifugal fan for internal kitchen

    I've recently refurbished my internal kitchen and the last thing I have to do is replace the existing Xpelair pull cord fan. Under current Scottish building regulations, I believe there is a minimal extraction rate and certain conditions required for ventilating an internal space. As...
  17. B

    Glowworm Boiler Firing control problem & Permanent Live

    All, There is a raised pimple but at the non cable end. I presume this still means its ok to replace. Additionally, if I did buy a new valve - should I buy normally open or normally closed? (I would ideally just take the valve and ask for a direct replacement to plumbers merchant)?
  18. B

    Glowworm Boiler Firing control problem & Permanent Live

    Thanks - Can you quickly talk me through the replacement?
  19. B

    Glowworm Boiler Firing control problem & Permanent Live

    All, Thanks to contributions above. Upon removing the grey DHW wire the system appears to function properly. As such, it is likely to be a failure of the microswitch on Honeywell 2 port DHW valve. Now...... Can you replace the Honeywell V4043 spring return valve head assembly without...