  1. M

    Detached garage - Earth

    no earth wire coming in, from rod or anything else
  2. M

    Detached garage - Earth

    I've just started replacing an old metal fuse box in the garage for a modern RCD CU, however the feed from the house doesn't appear to have an earth cable (only 2 core) although it is SWA which is glanded off so I suspect that has been providing the earth. I've checked the cable that feeds the...
  3. M

    3 Port Honeywell valve problem - V4073A1039

    Replaced the head, getting voltages as to be expected now but the valve is still passing heat all ways not matter what I have set (e.g. How water only, gives me CH and HW, same with CH only) so bottom half of valve also U/S by the sound of it :(
  4. M

    3 Port Honeywell valve problem - V4073A1039

    Thanks, fingers crossed that's the case, I'll fit the new head when it arrives this week(y)
  5. M

    3 Port Honeywell valve problem - V4073A1039

    honeywell v4073a1039 is the make and model of the valve I left it a while in both positions but I'll do another test before I resign myself to having to drain the system :(
  6. M

    3 Port Honeywell valve problem - V4073A1039

    Thanks for the explanation, I get that and suspected the head was knackered and have ordered a replacement (whole unit as it was no dearer) I still can't understand with the head off whichever way i turn the valve manually heat is sent both ways even with only hot water on
  7. M

    3 Port Honeywell valve problem - V4073A1039

    Would that explain not getting power on orange for heating only? Although, I'm pretty sure that's knackered but how is it that there is heating and hot water flowing when the valve is in either position?
  8. M

    3 Port Honeywell valve problem - V4073A1039

    Tested, all good apart from Heating Only, not getting power on orange
  9. M

    3 Port Honeywell valve problem - V4073A1039

    Heating system not working unless hot water is on Found buzzing from the 3 way valve, I've removed the top of it and the valve seems to move freely but not very far, see pics showing the valve movement, i seem to get hot water and heating whichever way it is so wondering if the valve itself is...
  10. M

    Soils pipe adjustment

    Thanks for taking time to reply I've kind of resolved the issue, the vertical soil pipe coupler was able to be turned slightly to minimise the angle, I can resolve the issue with either the magic flex joint or a floplast adjustable bend as I only need an angle of less than 20 degrees I'm...
  11. M

    Soils pipe adjustment

    When you say help do you mean tell me what I'm allowed to do or advise on a solution
  12. M

    Soils pipe adjustment

    I've moved my toilet to about 2 metres down the wall so have some internal work to do on the 110mm pipe The existing pipe pops out into the bathroom in the wrong direction by 90 degrees to where the toilet is, I plan to put a 90 degree bend on it so it is pointing at the toilet side, but this...
  13. M

    Honeywell Sundial Wiring Centre

    Hi, my Honeywell Wiring Centre has come just off the wall, and there is a cable completely unattached but the central heating and hot water seems to be working ok, I'm looking for some reassurance that this cable isn't needed As can be seen the only connections not made are heating valve but...
  14. M

    Very noisy when boiler starts up

    Yeah, the two black wires are now connected together, see pic
  15. M

    Very noisy when boiler starts up

    Yes the pipe with the pump on gets hot first thanks
  16. M

    Very noisy when boiler starts up

    Not sure if the pics or my rough diagram will help
  17. M

    Very noisy when boiler starts up

    Pipe goes into bottom of pump (inlet) then out of top (outlet ) into 3 way valve These pipes already warm, when I start the pump other pipes in airing cupboard get warm, not easy to trace as they disappear into floorboards