Search results

  1. gasanstuff

    Having a problem installing shower diverter (leaking!)

    :shock: Wow. Rip it out start again with the right stuff
  2. gasanstuff

    Water risk assessments

    REmoved
  3. gasanstuff

    Occasionally smelly toilet/basin mystery?

    If you washed your hands after you used the toilet then the smell wouldn't be there.👍 Fit the self sealing trap and tell whatever smelly urchin who has been using it to wash their hands.
  4. gasanstuff

    Water in air intake and fan unit Vaillant Ecotec 837

    The last one of these I did all worked ok when dried out, but the one before was gas valve and fan that went. It is luck of the draw, and obviously linked to how much water got into vital components!
  5. gasanstuff

    feroli modena e80 boiler - pricing a job

    Maybe he quoted for the prv complete with manifold, and expansion vessel is rear version so is installing an external with pipework and also adding a bottle of inhibitor in system when filled up.
  6. gasanstuff

    How Does My Open Vented Gravity fed System Work

    Direct has immersion heater Indirect has a coil and immersion heater
  7. gasanstuff

    Pricing

    exbg - got caught stealing hence the 'ex' lol
  8. gasanstuff

    Testing underfloor heating

    Assuming pipes are at 200 mm centre then hopefully pipes are the same length you may be ok, as long as heat loss calcs etc done and insulation up to spec. 200 mm centre equals 5m pipe per square meter.. 150mm centres then you may be in a spot of bother!
  9. gasanstuff

    Testing underfloor heating

    How many pipes are coming out of the screed?
  10. gasanstuff

    Support your local registered gas engineer

    True enough but I don't have a maintenance contract that I sell. All I do is continue the servicing etc. and now boilers have 5-10 year warranties then it does seem difficult to sign people up to these contracts seeing as they are covered
  11. gasanstuff

    Testing underfloor heating

    I always pressure test pipework and leave pipes under pressure whilst the screed is being laid. You may be ok but maybe not. Seems like getting a builder to do a plumbers job doesn't mean it's done correctly.
  12. gasanstuff

    Support your local registered gas engineer

    And over the last ten years the most any one customer has spent with me (annual servicing and repairs of a gas boiler.) Is around £1200. Had they been singed up to a maintenance contract that would have spent probably double that
  13. gasanstuff

    Efficiency:- LPG Combi v. LPG instantaneous Water Heater

    An Intergas is direct flame to pipe/heat exchanger as you put. and can be fitted on lpg
  14. gasanstuff

    Problem with Vertical radiator only heating some elements

    I have just done some work on a house that has had heating problems for 4 years. one problem was a vertical rad that was bought from B and Q. I suggested that it was upside down. customer thought i was taking the ****. In the end I took rad off and took it into the garden and removed...
  15. gasanstuff

    Boiler gone again

    Are you sure it pumps water from bottom and returns it so high?doesn't seem right to me
  16. gasanstuff

    Is this a fair quote?

    get a quote off Pimlico and you will see how cheap the quote you have is!
  17. gasanstuff

    Can hear noise at my house when next door uses water..

    Move their pipe outside your property.
  18. gasanstuff

    Heat Exchanger keeps blocking up

    Powerflush required. Not been done properly maybe? How was it powerflushed before?
  19. gasanstuff

    Boiler Flue gas analysis

    On all the readings? You need to find out what readings he is referring to, and what they are. And of course what legislation he is quoting. I recently had give a quote for a new boiler. Large national company had capped off boiler due to flue gas readings being off the scale. Took me...
  20. gasanstuff

    Fair boiler quote? and brand comparison

    It is pretty cheap to be fair.
Back
Top