Search results

  1. Diggory

    Boxing in - wiring and heating

    I think I understand (cable heat dissipation ?); is that a more theoretical consideration. Is 2.5mm^2 cable in a 25mm conduit any worse than under a galvanised channel buried in a wall chase ? Thanks D
  2. Diggory

    Boxing in - wiring and heating

    Thanks reply. So if ran a section of conduit inside the box and routed it as far from pipes as box would allow; would that suffice for separation. D:-)
  3. Diggory

    Boxing in - wiring and heating

    I’m renovating an old bungalow; fitting new rads and new/additional mains sockets to rooms. Is it okay from regs / good practice point of view; to box in 15mm copper heating pipes and my wiring (for new sockets) in same box. I’d planning to add the (dry lining type) socket into the same box -...
  4. Diggory

    Alternative to Gypsum - non cavity walls

    Looks I have some lime in the render and maybe the top coat skim too. D
  5. Diggory

    Alternative to Gypsum - non cavity walls

    Confess - I don’t really know. The wall is soft red with a (cinder ?) block internal - the gap is maybe an inch at best but it’s breached with mortar / debris. The wall is very cold and behaves like a solid wall. There is a traditional looking render and skim - how would I identify what type it...
  6. Diggory

    Alternative to Gypsum - non cavity walls

    …….internal repairs
  7. Diggory

    Alternative to Gypsum - non cavity walls

    I’m looking to patch repair some cracks and holes in an old solid wall. I recall being told not to use a Gypsum based filler as it would attract water /damp. On other walls I’m using ‘Gyproc Easyfill’ - but it’s Gypsum based. I’d be very grateful for a recommended alternative. Thanks in...
  8. Diggory

    What WC Fixing is this

    Yes. I suspect that the new raised hole centres would be too close to original holes to re-drill. I might be able to drill large holes where they are now and re-position the raw lugs off centre in a resin the likes of R-KEM. That’s a good idea - it doesn’t really take any weight as it sits...
  9. Diggory

    What WC Fixing is this

    Do you think a Diamond Round File allow me to slot the holes ? D
  10. Diggory

    What WC Fixing is this

    Thanks both replies. That might well be what I’ve got - not come across that before. If I pull it out, I’ll probably silicone it back down to the LVT without the screws. And yes - I’ve been thinking about the height increase. The pipe alterations don’t worry me, plus the pan connects to a...
  11. Diggory

    What WC Fixing is this

    I’ve got an IDEAL STANDARD WC - sits on the concrete floor / not rear concealed. It has two Phillips / cross head fixing screws about an inch up from base. They screw into nylon inserts, through the ceramic. They screw in horizontally - not downward into the floor. Does this suggest that there...
  12. Diggory

    Navigating DANFOSS TRVs

    I think I’ll give them a go………….. Any thoughts or recommendations Thanks D
  13. Diggory

    Navigating DANFOSS TRVs

    Hi there - I’m looking to purchase some DANFOSS TRVS. The range is quite confusing and I wondered if anyone would be kind enough to recommend. I’m looking for angled valve set pairs (inc lockshield). Plumbing is standard 15mm copper and new rads will have 1/2 connections. I quite like the look...
  14. Diggory

    Airing Cupboard Small Rad Vs Waste Heat

    Thanks clarification D:-)
  15. Diggory

    Airing Cupboard Small Rad Vs Waste Heat

    Good point - I can add a natural convection vent / grille to top and bottom of door (I’m assuming you don’t mean forced ventilation). D:-)
  16. Diggory

    Airing Cupboard Small Rad Vs Waste Heat

    Thanks - useful to know Best D
  17. Diggory

    BTU CALCULATIONS - IS THIS A CAVITY

    Thanks reply. I’m in the broad category you’ve referred to. My boiler is an ecoFIT pure 825 combi; 25 kW / 85,000 BTU. I’m not sure of a range bracket; in the way you’ve mentioned with a threshold at circa 6kW. The estimating tools suggest I need circa 27,000BTU over nine rads. I’ve got...
  18. Diggory

    Airing Cupboard Small Rad Vs Waste Heat

    Thanks reply. Not really - maybe some used / damp shower towels. And some general airing of clothes after ironing. Sounds like I should give it a try as it is - see how it works out. Best D:-)
  19. Diggory

    Airing Cupboard Small Rad Vs Waste Heat

    Hi there - I’ve recently switched to a combi (ecoFIT pure 825) and it’s installed in my airing cupboard after removal of the old hot water cylinder. Presently, it’s only running a small zone of UFH with the main flow/return for nine radiators not connected; so it’s not really being fully...
  20. Diggory

    BTU CALCULATIONS - IS THIS A CAVITY

    Thank you very much for your advice. Much appreciated. D