Search results

  1. W

    Leaking TRV pin-draining system?

    I would do a quick change over,close all rads at both ends,then shut both ends of the rad ,were trv is,then get bowl and old towels,undo the trv & go for it,2 min,if you dont panic,you can be done in no time,what trv is it,get the same type of nut
  2. W

    overflow from boiler

    Sorry i didnt read it properly,just made my own conclusion's,i didnt see copper
  3. W

    overflow from boiler

    Its a condensing boiler,so its working ok
  4. W

    combi problem

    Have you made sure the auto air vent is open.Also it does seem a circulation proplem,you said you checked the pump,but because it's spinning doesnt mean it's doing it's job.How quick does it stay on and does the flow get red hot coming off the boiler,could be a blockage but unlikely,so see what...
  5. W

    Worcester 28i Junior - Not Firing Up

    I would get the old pcb back in,i would be looking for a sensor fault,any corgi reg installer,with 1/2 brain,knows pcb's is your last part you will fit,i always check sensor's,thermistors,solenoids etc before i fit a pcb,also worcester technical is theree to help,im not ashamed to tell a...
  6. W

    Neighbours from hell

    My mum got neighbours next door who from day one upset her,now i had a few words with them over a few months,but then they got nasty,and she got frightend of them,he knocked and demanded £50 or he would smash her window or maybe even find gunshots at her house,so i went to sort it out and i did...
  7. W

    combi pcb

    Agile you'd think so,but ive been to worcester's were the live from the s/spare is connected to the neutral on the pcb and neutrul to live,and it gets as far as the main jets firing,but ignition keeps sparking until the main jets cut off,and when feed is corrected it works ok,no harm done to any...
  8. W

    trv's have been fitted to NON flow end of new rads is this o

    New trv's are made to fit on flow or return,so as long as they have arrows on them showing they can flow either way your ok
  9. W

    combi pcb

    Is it igniting,then the burner is cutting out after 10 secs,or is it just sparking. If it's firing then it may not be pcb,it could be its not getting to thee flame sensor,does it carry on sparking even when main flames come on,if it does keep sparking,then have you had any work done on the...
  10. W

    Re-igniting bolier

    Is it the boiler with the brown bottom that slides out,if so just remove that,then undo the 4 screws and get a taper and press green button,and light,it is easy and only takes 5 min
  11. W

    Combi water pump - will it still work?

    Have you 240v at the pump?
  12. W

    Combi boiler problem

    Is it doing it on heat & h/water,if so then check it could be something connected to the fan,maybe the venturi blocked,aps tubes,its firing but not staying on,so maybe the fan isnt running quick enough,has the boiler casing been off lately?,or has it got a black or red cap on top of the...