    Wiring for Bathroom Mirror - Want to use old shower switch.

    If the mirror has an issue in the future, will it not stop all the lights on the same circuit from working? Trying to understand best practice!
  2. A

    Wiring for Bathroom Mirror - Want to use old shower switch.

    Why do you suggest lighting rather than shower feed? The shower has been removed, are you suggesting leaving it there ready for any future use?
  3. A

    Wiring for Bathroom Mirror - Want to use old shower switch.

    That's right, its on the ceiling by the entrance door to the bathroom.
  4. A

    Wiring for Bathroom Mirror - Want to use old shower switch.

    Makes sense. Do you know if its acceptable in the eyes of building regs to put an unswitched fuse box in the ceiling where the socket for the old pull cord was? i.e. its in Zone 3 but its in the bathroom.
  5. A

    Wiring for Bathroom Mirror - Want to use old shower switch.

    We're planning to install a bathroom vanity mirror to an appropriate moisture zone in the bathroom. We've just removed the electric shower which had a pull cord switch in the bathroom. There's a permanent live to that switch we want to use. The "shower" has its own circuit on the CU downstairs...
  6. A

    Terraced Housing - Different Gutter to Neighbour Join Issue

    Hi all, Just moved into a new house and there’s bad damp and swelling downstairs caused by a faulty join between my gutter with neighbours. I have square guttering, as do most of the street, and as do the ones the other side of my neighbour, but my neighbour has ogee. The union appears to...
  7. A

    What is this layer under plaster?

    Would you remove it from the brick before mounting cement boards?
  8. A

    What is this layer under plaster?

    Stripping back tiles in the bathroom of an early 1900s terraced house. Under the tiles was the layer of plaster, but there is another layer underneath that, that looks almost like a cement type render? We're planning to install cement boards prior to retiling but we're unsure if this layer...
  9. A

    Fitting a 700mm Wide Radiator in place of 1440mm Radiator - Question

    Hi Folks, As per title, installing a double panel radiator that's approximately half the width of its single panel predecessor. I was hoping (for the time being) to not have to cut the existing pipe and soldier new connections, and was thinking of using 2 x ~400mm valve extensions, but they...
  10. A

    Hive Wiring Question for Worcester Greenstar 24i Junior Combi (with pic)

    No seal. For anyone wondering, the answer to this question was yes. All done and working fine as per diagram in post #1 which is also the same wiring as used here
  11. A

    Hive Wiring Question for Worcester Greenstar 24i Junior Combi (with pic)

    Thanks Stem. And N and L from fused supply into hive also? FUSED SUPPLY N + L ---GO INTO---> HIVE N & L Terminals ---> FROM HIVE N & L ---GO INTO---> into BOILER L & N (Im comfortable with the 1 + 3 connections, just concerned I've not understood the flow above here correctly).
  12. A

    Hive Wiring Question for Worcester Greenstar 24i Junior Combi (with pic)

    Hi Stem, Thanks for the reply. My boiler appears to be plugged into a 3 pin socket in the wall. It has a fuse inside the plug. But to clarify, with power coming in from the fused supply, does the diagram still stand - as in, the supply of L and N comes from the fused supply, into the hive...
  13. A

    Hive Wiring Question for Worcester Greenstar 24i Junior Combi (with pic)

    I'm hoping someone can confirm the wiring before I go ahead and (hopefully not) cause some damage. I'm wiring just a Hive Heating system, the water is on-demand and not set via timer. I'm planning to do the following: Questions I have: 1) Does that look right? Will I have two wires...
  14. A

    Which Hive Heating Do i Need?

    Hi guys and gals, Long time lurker here taking the plunge on my own Hive Heating installation, but I have a couple of questions of what exactly I need. Any help much appreciated. I have a Worcester 24i Junior combi boiler. Currently, there is a mechanical timer for the heating on the boiler...