  1. Exedon

    Does this speed fit need any work?

    That's a rough mess IKEA unit with no service void? As above check for inserts id be putting the wm tap in the unit.
  2. Exedon

    Mains water shut - off valve handle question

    You have the valve that's fitted commonly in Anglian water area DO NOT overtightened they can lock down and not come undone! I've never done it but know others who have.
  3. Exedon

    Not Getting Hot Enough!

    I'll have a bet that the pipework is restricted with crap. Pic of one we sorted.
  4. Exedon

    Not Getting Hot Enough!

    Tank feed / open vent id be checking pipework with a magnet around open vent/ cold feed area.
  5. Exedon

    Soil manifold missing grommet

    That looks like a hepworth (wavin) soil manifold. They are still made so maybe spare grommets are available.
  6. Exedon

    Loctite 55 leaking radiator tail

    Well you have managed to do what ive never seen after many thousand of threaded joints and get a leak with loctite 55! We probably use more cord (don't bother counting) and tighten more . No you can't do any damage nipping it up more.
  7. Exedon

    Redfyre 100 oven thermostat

    Try speaking to Harworth Heating That looks to be a similar thermostat that's fitted to the thermorossi/bosky cooker.
  8. Exedon

    Can i sync the EPH CP4i using ember app to thermostat?

    If you got your ephcp4i as a set and you have linked the gateway to yor WiFi yes you can do all settings from your phone . It's a very quick easy set up.
  9. Exedon

    Old hep2o pipe

    Yes always insert same manufacturer as tube.
  10. Exedon

    Can someone tell me how to isolate my hot water please

    Lever valve on back wall with red handle If installed correctly should push down (fall to off)
  11. Exedon

    Why are there no old school heating engineers?

    I'd Certainly try a chemical flush you can probably do the drain down and refill yourself. If it works cost of power flush saved.
  12. Exedon

    Replace traditional with bar mixer shower

    As above ive managed to do it couple of time when pipework in stud wall using a fast fix kit. By the way matt black brasswear soon looks crap unless you have a obsessive cleaner.
  13. Exedon

    Why are there no old school heating engineers?

    For anyone with half a idea strait forward. Undoubtedly blocked near pump/open vent cold feed connection. Repipe add decent filter refill add X400 run for 4 weeks drain cold flush if needed . Refill adding inhibitor. Run of the mill stuff but not as well paid as throwing a combi on wall.
  14. Exedon

    Central heating layout. This should work, right?

    Take you spoke to Worcester? Doubt they know one end of a camray from another. Which mode of camray? 3 or classic? Perfectly simple to convert to sealed system done many some from new others retro fit.
  15. Exedon

    Why are there no old school heating engineers?

    But a young one ! First fitted a boiler (under supervision) in early 1969 vulcan autostat. Still working fitting a 70kw Grant next week. As above don't get a combi especially from s box slinging team.
  16. Exedon

    Leak between stopcock and water meter

    Yes the white hexagon is shut of valve. There should be a black plastic extension to fit in it . Br carefully not to tighten down too much I've seen then open again. But as mentioned from your boundary onwards the service is your responsibility.
  17. Exedon

    Central heating layout. This should work, right?

    Probably not what you want to hear but I would seriously consider converting to sealed system. Simpler pipework no open vent or feed tank. With existing boilers we generally run system at 0.2 bar above system head.
  18. Exedon

    Central heating layout. This should work, right?

    I would strongly advise against a combined vent/feed . I used to see them on a regular basis (heating team in this area were very fond of them) odd ones can be OK but I've regularly found systems to be absolutely filthy. Plus as already mentioned combined vent/feed systems are notorious slow &...
  19. Exedon

    Riello RDB1 skips a beat

    Is your boiler installed on a standard low level flue?
  20. Exedon

    Riello RDB1 skips a beat

    Probably needs eye's/ears on! Take it you have a combi?