    Some System Planning Help

    dynamic pressure reading is what you want but i cant think yours is not going to be very good with a static of 12 and a good flow rate.
  2. B

    Getting enough run on bath?

    shall traps are good for replacing like for like as most old metal traps were that size. Alot of new builds jobs still use shall bath traps because of the depth of the bath and not being able to sink the trap into the timber floor. Its not right but its done.
  3. B

    Question for the Gas Guy's Re Condemned Gas Fire

    BG like other large companies have some really good and some really bad engineers. I know some good and they offten tell me about the bad which normally makes me laugh and sometimes alittle shocked. Large companies are capable of covering up mistakes quite easy as its there other engineers that...
  4. B

    Pressure testing radiator pipework

    follow the hep2o testing instructions, dont leave the test on for long peroids at high pressures. use water test pump. air testing can be dangerous and should only be done by a competent person with good PLI.
  5. B

    Brass stop cock and MDPE pipe

    if its spinning its not tight enough or the olive is to big, you do sometimes get them like this (poor manufacturing normally). take it back and swap it, cut the pipe down and start again making sure you use the copper insert. leave a good 4 ot 6 inches above ground or cupboard level for future...
  6. B

    Plume from boiler causing nuisance - how to resolve?

    Although part j states 600mm and many manufacturers state 600mm is ok there are other guidelines that state other distances when a nuisance factor is taken into consideration. Even with these distances if the flue causes a nuisance then it really needs addressing or can be forced to be addressed...
  7. B

    Brass stop cock and MDPE pipe

    if its compression and spinning the its not going to hold wata.
  8. B

    soldering

    if the fitting and the pipe is new and clean then cleaning is not really needed with powerflow but if your new to soldering then its advisable as it will run better.
  9. B

    Question for the Gas Guy's Re Condemned Gas Fire

    probably just a bad day to test spillage, wait till the wind picks up and get it retested.
  10. B

    Improving on TRV

    this post is funny and also full of total ******s. maybe i will see the end on dragons den with a sales pitch of some expensive control and Debra will pull a trv out her pocket and say this cost 9.99 and works im fekin out!! haha
  11. B

    Water pipe snapped off , could do with some advice

    get a plumber in or if its gas a gas safe engineer.
  12. B

    Improving on TRV

    common misunderstanding is that a trv controls the radiators temp not the rooms. a remote head trv will move the sensor away from the radiator.
  13. B

    Baxi Combi Instant 105e - Pressure Dropping 3 Times A Day

    it sounds like you need a new / external expansion vessel fitting and maybe a new prv if the old one cant hold water back now its operated.
  14. B

    Noisy new bypass radiator !!

    not really such a thing as a bypass radiator, yes the one in the index room with the room stat should not have a trv but an auto bypass should be fitted if needed by the boiler manufacturer or systems design.
  15. B

    Combi Make & Model - Quote Purposes

    the cost of the same boiler will be simular from each quote you get in most cases, what you need to gauge is the quality of the installation which can be hard. The person giving the quote will need to check your water supplys pressure, flow and hardness, the gas pipework sizing which will likely...
  16. B

    combining bath and basin waste

    its done alot, not best practice but sometimes its the best solution. 2" if possible.
  17. B

    Soundproofing Boiler Cupboard?

    check the boilers instructions, most can be screwed to timber now but maybe a layer or two of sound proof plasterboard would help the sound issue. if you can fix studs floor and ceiling then that may help.
  18. B

    Gas leak ?

    good to know its got sorted :)
  19. B

    fitting slightly over heated

    yes if it solders correctly. If your learning soldering its best not use a turbo type torch but use a smaller flame.
  20. B

    Soundproofing Boiler Cupboard?

    stud the wall out and fill the gap with sound proof insulation.