Search results

  1. C

    Fitting a shower

    Hey guys you seem to just be proving to each other what can and cant be done.My shower would be about 25 to 30 feet from my fuse box. Nearly straight up above.My question now is would there be something in the loft to feed new wire down to the consumer unit. I don't seem to have a 45 amp fuse...
  2. C

    Fitting a shower

    Its a Trinton forte 9.5 kw,I bought new .
  3. C

    Fitting a shower

    Hey all,I need some help,how can I get the wire to my shower in the upstairs bath room to the fuse box down stairs,is the any way to feed the wire from the loft to the fuse box. Please help my kids are costing me a small fortune with heating the water with the heater.
  4. C

    GATEWAY LAPTOP w340ua screen wont come on ,even external

    Cheers Dave, I GUESSED that the motherboard was faulty,but was hope not,and looking to se if anyone had this problem and fixed it.
  5. C

    GATEWAY LAPTOP w340ua screen wont come on ,even external

    GATEWAY LAPTOP w340ua screen wont come on even external monitor still dont work,check memory,removed hard drive,contacted gateway,they told me to try a few things but no luck. The blue power light come on and the cd light flashes but no sign of life to the screen. Anyone come accross this and...
  6. C

    Oil not coming from the suntec pump. HELP

    FITTED a pressure guage and its 105 psi,not a bad guess.. These are the settings for my burner. Just need CO2 Checked. Output in BTU’s 90,000 0.85 x 80° EH 110 PSI 11.5 co2
  7. C

    Oil not coming from the suntec pump. HELP

    i altered the adjusting screw for pressure,it has a spring and a nipple inside,Its a 17mm bolt type and threaded inside with a grub screw that can alter the spring tension using a 4mm alan key.The grub screw pushes the nipple onto the spring.I found that adjusting adding less pressure to the...
  8. C

    Oil not coming from the suntec pump. HELP

    ITS WARM IN MY HOUSE TODAY. :D :D :D :D :D :D
  9. C

    Oil not coming from the suntec pump. HELP

    So the story now is I took back the coil I bought yesterday and bought a photocell just to make sure now since I had it starting but cutting out. Just fitted the photocell and we are getting Heat YEPEEEEEEEEEEE.( I can take of my jumper now) Cant thank you enough for all your help. So seems...
  10. C

    Oil not coming from the suntec pump. HELP

    Photos of my suntec pump. Photos added to my photos all can view
  11. C

    Oil not coming from the suntec pump. HELP

    Good morning John,just to let you know how its going now,I have the boiler starting now pumping oil and lighting then cuts off after a few seconds. When I fited the pump back this morning and still not getting oil I adjusted the screw holding the spring in the solenoid valve and the less...
  12. C

    Oil not coming from the suntec pump. HELP

    Hi John,another day at this boiler. I have taken some photos off the pump.I can email them to you.(what is your email) PM ME. I striped the pump last night and it was very clean no sludge or anything,I took the solenoid shaft off to see if i could see anything that was maybe jamming it all i...
  13. C

    Oil not coming from the suntec pump. HELP

    Hi again jOHN. This unit has the fan to the lefhand side then the motor in the middle and the pump next.(FAN.MOTOR.PUMP. i took the pump out and the Plastic coupling is like new ,and the pump turns freely.Unless the solenoid valve has stuck closed.The pump would not go back into position...
  14. C

    Oil not coming from the suntec pump. HELP

    I am not sure then about the coil,I thought it would magnetize when switching.there is oil at the primer side of pump ok,and pump Is turning,well the fan is turning.
  15. C

    Oil not coming from the suntec pump. HELP

    hi again John. Should the Solenoid coil not magnetize ,I removed it from the shaft and held a screwdriver inside it did not.I checked the Kohms on the coil connection and reads approx .100 when dark and .002 when shown to the light.
  16. C

    Oil not coming from the suntec pump. HELP

    Yes oil at the pump and pressure is good when I loosen the pressure screw. Should the Solenoid coil not magnetize ,I removed it from the shaft and held a screwdriver inside it did not.I checked the Kohms on the coil connection and reads approx .100 when dark and .002 when shown to the light.
  17. C

    Oil not coming from the suntec pump. HELP

    Hi John,I fitted a new coil and still no luck,I opened the pressure screw a little and oil is coming into the pump,I am lost now ,could it be the Satronic TF830/B control box,or the photo cell.Is there anyway for me to check.? How do i check the resistane of the photocell,what do i set the...
  18. C

    Oil not coming from the suntec pump. HELP

    when i attach the metre to the coil socket the voltage goes up and down its not a content reading. I can not find a solenoid coil at www.heating-parts.co.uk. Ps. I REMOVED the pump to check and all looks ok the coupling is like new,and it turns freely.Do you think its a faulty coil,or...
Back