  1. G

    22mm / 3/4" straight through wall plate flange

    Dont make them because there is no demand for them . Here is an elbow type . if you dont want to go with madrab idea https://www.bes.co.uk/pipe-tube-fittings/pipe-fittings/compression/compression-wallplate-elbow-22mm-x-3-4in-17717/
  2. G

    Sentinel inhibitor

    No it wont clear sludge you need x400 first then once flushed you add x100 . X200 is a silencer and will quieten noisy boilers
  3. G

    Baxi 105e

    on both then initially change the main sensor in the dry pocket
  4. G

    Magnetic filter.

    DO NOT TOUCH the isolating valves unless you want a very high chance of them leaking Plenty of room ? there is about 6 inches of pipe on show
  5. G

    Baxi 105he pump pulsing on/off

    yeah venturis fall apart usually show up first on thermostatic showers , Tip to get all the bits out tape a bit of hose pipe to your hoover hose and quick switch on gets all the bits out
  6. G

    Baxi 105he pump pulsing on/off

    only ever had the lead to a 105 gas valve faulty once and that was about 20 years ago there is diodes in it seemingly , yep a strange one
  7. G

    Essex flange, ect

    what temp is your cylinder stat set to because if its too high cavitation can occur in the shower pump So keep it below 60 degrees
  8. G

    Baxi 105he pump pulsing on/off

    Worth checking for a neutral fault to
  9. G

    Baxi 105he pump pulsing on/off

    certainly a head scratcher
  10. G

    Baxi 105he pump pulsing on/off

    long shot Have a look at the condense trap there is two wires on top of it pull the one at front off see if it fires up .
  11. G

    Magnetic filter.

    i wouldnt bother then
  12. G

    Baxi 105he pump pulsing on/off

    very strange fault Was it a brand new pcb or reconditioned and definitely not an instant pcb by mistake . Earth wires from and to pcb re connected /altered Correct wires put back on sensors / red to ch sensor green to hw sensor Has anything else been done to boiler ? Polarity well worth a check
  13. G

    Magnetic filter.

    Do all your rads heat up with no cold spots
  14. G

    Baxi 105he pump pulsing on/off

    when you say nothing happens when hot water runs . do you mean no demand light comes on and it doesnt fire ? Does the pin come out and hit the microswitch
  15. G

    Baxi 105he pump pulsing on/off

    105 instant ?
  16. G

    Gas Pipe size questions

    i have given you the charts given/given you the online calculators and the figures that agree with what i put . I told you to read what the original poster said they had and to stop making up in your own mind what they have and waffling away talking shyte . I am not here to educate you its...
  17. G

    Pipe centre to centre measurements 2 x 110mm 45s.

    i would go 120 to 130 but unless got them to hand its guess work depending on length of male part
  18. G

    Baxi 105e flame and flue light flashing together

    two flashing lights on a 105 is a new board required 99% of the time . No the rad water cannot mix with the water coming out the shower she must be smelling the drains or something else
  19. G

    Pipe centre to centre measurements 2 x 110mm 45s.

    it all depends how long the male bit is that goes into the female socket More information required on what it is that is 110mm
  20. G

    Gas Pipe size questions

    Why are you speaking to yourself ? first sign of madness . I would go as far as saying you are round the pulled bend so from now on i will just give you the elbow