  1. CountryFan

    Bonding

    Maybe this is of some use? https://electrical.theiet.org/wiring-matters/years/2019/75-may-2019/to-bond-or-not-to-bond/
  2. CountryFan

    Is “I cannot see any asbestos” a valid reason to close this case?

    Private or social housing landlord? If the latter point them towards Awaabs law, Riddor and COSSH if the former then probably just COSSH and Riddor.
  3. CountryFan

    Thermowatt immersion heater - cable strain relief

    I think they could be correct, probably just the orientation, for which they cannot assume where the hole will end up
  4. CountryFan

    Thermowatt immersion heater - cable strain relief

    Yes the last photo appears correct, but I can’t find the instructions online, could you post a photo of the bit you mention?
  5. CountryFan

    Cistern only filling part way up/weak flush

    It looks to me like the fill valve is catching on the cistern.
  6. CountryFan

    How to replace a leaky WC Cistern syphon

    Ime, it’s usually the float valve passing water via the internal overflow, not the actual syphons.
  7. CountryFan

    Fluidmaster fill valve

    Not entirely sure, but it's either a slight turn and lift off or just lift off. Maybe this can help?
  8. CountryFan

    Fluidmaster fill valve

    Definitely a fill valve, not the syphon
  9. CountryFan

    Changing soldered joint for push fit/compression

    Pre soldered (possibly Solder ring you’re thinking of) need the pipe clean, fluxed, clean of dirt/debris et al, no water in the pipe and heat applied.
  10. CountryFan

    Is This Boiler Finished And Needs Replacing - Valliant

    Salvageable imo. Might need a new back rail, but ultimately looks like the condense hose has failed (common on this year/model), it even looks like it’s not attached and, if that’s the case, then your boiler man should have turned the boiler off and issued a do not use sticker and warning...
  11. CountryFan

    Cape Verde

    I only saw a bit of it last night. There seemed to be some bias towards Uraguay, and there seemed a lot of shoving. Uraguay deserved a conceded goal after that GK blunder - was it David James in goals? :ROFLMAO:
  12. CountryFan

    Vent pip in loft in the way

    Au contraire https://www.plasticpipeshop.co.uk/75mm-2-12-Grey-PVC-Pipe-10-bar-PN10-25m-Length_p_5317.html, just ain’t cheap!
  13. CountryFan

    Vent pip in loft in the way

    Your last photo shows a white cowl, which is an air admittance valve - can this be swapped with your proposed stack?
  14. CountryFan

    Vent pip in loft in the way

    Yes it can be reduced in size to not less than 75mm for single or 2 storey properties. Or perhaps change the air admittance valve on the other one for the 110mm on existing and vice versa.
  15. CountryFan

    Tiger loop smells

    Contact your installer would be first port of call. I don’t hold oil fitting qualifications, but sounds like it could be combustion related, so possibly plausible. My advice is to stop using it immediately, you could have a carbon monoxide issue.
  16. CountryFan

    Vailant Ecotec 837 - hot water intermittent - Help

    It can still affect it, or another mixer. Basically the cold pushing the hot out of the way. Isolate the cold inlet to the boiler and test hot outlets including the shower.
  17. CountryFan

    Vailant Ecotec 837 - hot water intermittent - Help

    When it next happens feel the flow pipe under the boiler
  18. CountryFan

    Combi with hot water tank - no HW

    Yes, there should be a motorised valve and it will be on the pipework, this then receives a switch live from the programmer and cylinder thermostat and then sends a switch live to the boiler.
  19. CountryFan

    Replace analog timer?

    Either, but you need to tell them exactly what you have and what wants doing as not all of both trades are competent to do this type of work.
  20. CountryFan

    Tight toilet flexi kinking

    I would go with an extension piece with a straight connector or angled/offset if required