    Another Extract Fan Query

    it appears to be thanks.
  2. P

    Another Extract Fan Query

    so live and switched live were wrong, so the fan went on and off with the lights, no overrun as the swtiched live was in the constant live of the fan. when is was wired correctly, the humidity sensor was set too low, so the fan stayed on to lower the humidity. so when i set the humidity...
  3. P

    Another Extract Fan Query

    it went off after some time, set the humidity to 90% so must have been a hunidity setting issue, thanks
  4. P

    Another Extract Fan Query

    yes it is an overrun fan with humidity sensor it is set to 15min overrun but, if i wire it up as suggested it comes on woth the lights but will not go off regardless of how the timer is set
  5. P

    Another Extract Fan Query

    Ok re-wired it so BL-N, GB-SL, BR-L overrun set to 15 humidistate set to off came on when the lights came on, waiting to see if it turns off after 15min what do recomend i set the humidistate at?
  6. P

    Another Extract Fan Query

    thanks, sorry what i meant was i can't seem to wire it so that the overrun works, it just goes off woth the lights and won't overrun
  7. P

    Another Extract Fan Query

    I have recenly replaced my old extract fan in the downstairs toilet with a new fan as the old stopped working I have a Black (BL) - Grey with a piece of brown tape (GB) - and brown (BR) i have assumed BL=Neutral, GB (switch live), BR (live) but, that turned the fan on, when the lights went...