  1. C

    Anything obvious?

    thanks for the replies found a date sticker on the CU of Apr 2007 so must have been installed about then. Opened up the CU looks a bit/lot messy in there!! :shock: The large grey T&E 10mm fed from the 40a mcb is the supply to the garage it transfers to a box before going outside and then fun...
  2. C

    Anything obvious?

    My brother just moved into a new place had a look at the electrics all seem quite new, just wondering if anything looks glaring wrong/dangerous especially the earthing block is this usual?? What type of earthing arrangement is this? The tails are 25mm and a newish split load board. Advised...
  3. C

    Washing machine Shock not switched on????-NOW FIXED WITH PIC

    thanks harry. I have been running the washing machine with this setup for over 3 yrs and it has worked perfectly would it not have any adverse effects on the machine???
  4. C

    Washing machine Shock not switched on????-NOW FIXED WITH PIC

    oh dear here is the prob-all now fixed and dunno what the red tape on neutrals are all about all now sorted. Thanks
  5. C

    Washing machine Shock not switched on????-NOW FIXED WITH PIC

    my initial thought was swapped wires in the socket I will check this now. update in a bit.
  6. C

    Washing machine Shock not switched on????-NOW FIXED WITH PIC

    right ok, makes sense it was on standby for some hours before i took it apart. thanks
  7. C

    Washing machine Shock not switched on????-NOW FIXED WITH PIC

    Hi, Very strange situation today wondering if anyone could shed some light please. My CANDY washing machine was not draining well, took apart the top to access drain pipe inside machine. Found blockage, removed, and started reassembly. Accidently touched live connection inside and OUCH shock...
  8. C

    11kv Circuit Breaker

    :shock: What the hell do the busbars look like that these are mounted on!!! :lol:
  9. C

    Posh Shed at the end of the Garden

    My logic comes from the fact that the pics you posted prove in no uncertain terms you cannot crimp. I care not if your work is a fire hazard but as you so rightly say start a new topic regarding your inability to crimp and I will advise.
  10. C

    Posh Shed at the end of the Garden

    what relevance? please you are the one alledging the op is taking the P**s, me thinks it is you taking the p**s making such allegations and you cannot even crimp correctly oh dear!-the words people and glasshouses spring to mind! just for the record this was put in my last post but now...
  11. C

    Posh Shed at the end of the Garden

    What relevance???? Please!
  12. C

    Posh Shed at the end of the Garden

    I read these forums a lot and take a lot of good advice from them. But I feel I must respond to the reply BAS has given in this thread. What makes you such an expert, judging by your own attempts of electrics which you posted pics of last week I fear you are the one in need of serious...
  13. C

    Nail through Sky TV Cable.......

    Just cut away damaged piece and rejoin with the proper connectors, same thing happened to me did above suffered no signal loss whatsoever.
  14. C

    Chest Freezer on RCD?

    I am buying a chest freezer to put into my garage, install in garage is a 10mm SWA from 40amp breaker in house CU running 32m to a 2way RCD CU in the garage with 32amp MCB supplying sockets and 6amp mcb supllying lighting. The CU in the garage is not a split load board it is all covered by...
  15. C

    Is my bonding wrong?

    After reading a few posts on here recently about bonding of pipes i decided to look at how my kitchen pipes were bonded. They have earth clamps with the "do not remove" tag and have 6mm earth wire connected to each pipe and then I've followed it back to connnection in an earth terminal in...
  16. C

    Junction Box on Ring main

    I have discovered a junction box on my kitchen ring main when I pulled back the plasterboard to renew. The MCB supplying the kitchen ring is 32 amp but the Junction Box is a 30amp one. I am not quite sure what purpose this junction box is serving (cable extension possibly???). Obviously...
  17. C

    Cable Size

    Now you mention it prob did say SQ. Thanks for the advise guys.
  18. C

    Cable Size

    The cable is fed from a 40 amp mcb at the house CU, then runs to a wylex RCD two way CU in the garage supplying 1x6amp MCB for lighting and 1x32amp MCB for a ring main in the garage. Appliance wise he is running a small under counter freezer, tumble dryer, washing machine, PC, microwave and I...
  19. C

    Cable Size

    My friend has just moved into a new house. He has a detached garage with SWA cable running from the house CU to the garage 2 way CU. He claims this cable is 16mm SWA however I'm not so sure and think it is 10mm. Could someone please advise to settle an argument, the following is on the side...
  20. C

    Outside light query.

    yes i was wondering this, is this acceptable reg wise to do?