    down-lighters in plastic cladding

    Advice please, I have been asked to fit a number of downlighters in a plastic cladded ceiling.Any advice/reference on particular make/model. Regards
  2. E

    Tips on Heat Shrinking Joints

    When heat shrinking joints what is the best size sleeving for 2.5mm crimped joints. And what is the preferred method for applying the heat. Regards
  3. E

    Extending Ring Main

    Is it permissable to extend a ring main by taking the cables out through the back of a socket, into plastic conduit, along the outside wall and then back in to building further along the wall?
  4. E

    Cable Tracer/Tracker

    Has anyone got one of the above, if so are they worth investing in and how do they actually work? Regards
  5. E

    Broken Ring!!

    Ideas please, When doing an initial check for continuity at the ends of a ring it became apparent that there was a brake in the CPC loop. After checking all the sockets on the ring for loose connections no termination fault was found. A broken CPC somewhere in the cable seems favorable but...
  6. E

    Insulation Resistance Testing

    Advice please When testing a rcd protected circuit where and how would the test be carried out? Should you unplug everything on the circuit under test or just switch it off at the socket. Cheers
  7. E

    Wall light back box

    Does anyone Know if a wall light which is fixed to a block/plastered wall needs a back box, or can the block/plaster be chopped out to a suitable depth and the connections be done in a standard term block. Nowt in OSG. Cheers
  8. E

    Extension Radial circuit

    Advice Please About to install a radial circuit for an extension. The feed will come from a spare 30A plug in mcb from an old wylex cu and run in 4mm T&E. There is currently no RCD protection on any of the circuits and my concern is that this new circuit will probably feed appliances outside...
  9. E

    diversity assistance

    Assistance please Existing Installation 2 x 32A Ring mains 2 x 6A light Circuits 1 x 20A Shower Supplied by a 60A service fuse Proposed new circuit to feed 2 x 3Kw heaters and 2 socket outlets from spare fuseway in cu My question is can the service fuse/cu handle this extra load
  10. E

    Which Test Equipment?

    Thoughts please, Currently in the process of replacing my old test equipment. Capable of the routine tests - Earth loop, Pscc, Rcd, Insulation resistance etc.... £700'ish to spare All in one seems favourable financially. Recomendations please :?: :?:
  11. E

    Terminating SWA in a Consumer Unit

    Thoughts Please, I'm about to install a 20A radial circuit to an supply an extension. For the ease of installation the feed will come directly from the CU and be run though the garage wall in 2.5mm 3 core swa to a plastic termination box (ip56) on the extension wall. From here the it will be...
  12. E

    How Many Sockets?

    Question. Am I correct to say that a 13A fuse spur can feed any number of socket outlets, almost like adding a mini radial?
  13. E

    Part P Delayed

    I Hear that legislation Part P has been put back until March 2005. Too many companies struggling to register by 1st Jan. Anyone else heard anything.
  14. E

    Brick Lights for Conservatory

    Welcome advice required, Going to install 4 brick lights to a conservatory base as it is built, here's the plan. (i) Chop in a 5A unswitched fuse spur fed by the ring main at socket height (can't pick the lighting circuit ) (ii) From here run to a plate switch (iii) From the switch to the...