  1. D

    install cost

    Grant vortex utility system boiler 26/36 and an Ariston 210 primo cylinder. fully fitted and old boiler and loft tanks removed. Is £ 5250 excessive?. Looks like labour costs are more than for equipment. If reasonable is the above boiler and tank big enough for 19 rads and 2 baths
  2. D

    Does part P go far enough?

    I am a doctor. MB ChB, FRCS, FCEM. Lots of people self treat. I apologise for saying anyone can do it, you have to have practical and theoretical skills. Actually there is alot of similarity about understanding how the human body works and plumbing, electricity etc. Vascular surgeons...
  3. D

    Does part P go far enough?

    building control have passed it. paid the fee all inspected. The were not interested in testing, just inspected the job. You can DIY to save money, or DIY to spend the same money but use better quality materials. Electrical installation isnt rocket science, anyone who reads up on it, has a...
  4. D

    Does part P go far enough?

    I do DIY electrical stuff, just wired new garage, Building Control aware. Used Hager waterproof CU, Hi Tuf and armoured cables, MK metal clad switches and sockets. Wire it up myself, check for continuity and any direct shorts, switch it on, then use socket tester to check earth fault loop...
  5. D

    wiring ring main

    with ring mains when going from room to room is it OK to come up the wall in a channel then go throught the wall behind the socket, then come out in the other room into a socket, and then carry on the circuit into a channel and down and under the floor boards. or is it best to go through...
  6. D

    fixing 4 x 4 timber to steel lintel

    whats the best way of fixing a 4 by 4 piece wood to steel lintel, more cosmetic than strength needed, can you get large self tappers, and if so where?
  7. D

    buried SWA cable

    thanks for your excellent quick advice, I thought it would cause problems. Now using cleats, do you have the screwhole above or below the cable?
  8. D

    buried SWA cable

    need to bury some armoured cable under concrete, is it alright to run it through blue MDPE pipe which I have spare?. Worried Building Control may worry in the future that someone thinks its a water pipe and cut though it.
  9. D

    treating roof trusses

    do roof trusses such as Donaldsons come pre treated? If not do you have to treat them before you lay the felt?
  10. D

    roof truss treatment

    do roof trusses usually come treated - ie Donaldsons. If not do they need treatment before felt or tyvek put on?
  11. D

    CU and conduit

    yes, I must admit with box conduit have always kept T+E intact if possible. I just thought using 3 proper wires rather than T+E and subsequent G/Y sleeving would be better if the grey insulation stopped short of box.
  12. D

    CU and conduit

    have 50 x 50mm conduit from CU to 40 amp junction box. Space tight in CU, is it acceptable to run 6mm singles from CU to junction box, rather than 6mm T+E, thanks
  13. D

    Garage Electrics

    Understand Part P and Building control and spark involved. new garage electrics two questions please 1. Do the new 17th edition rules apply to garages - ie CU and sockets below 1.2 metres? 2. Is it better to run SWA underground or along the side of a wall - underground more cosmetic but...
  14. D

    SWS Security shutters as Garage doors

    Has any one used these for a secure roller garage door, are they weatherproof?. Also for sectional doors are Henderson G60 worth the money
  15. D

    building new garage

    building larger new garage on top of site of old one. builder wants to cut through old floor slab (6 inch) for foundations and leave old slab in place rather than break up old slab and put in hardcore and new floor. is this acceptable?, plans state to put in new floor, will building control get...
  16. D

    TN-S earthing

    its part of an old well and pump - no motor now
  17. D

    TN-S earthing

    3 core 2.5mm armoured cable, one core earth plus armour. 4mm G/Y from here to metal pipe. Should I replace this with 10mm?
  18. D

    TN-S earthing

    in a TN-S earthing system, when you have a supply going via armoured cable to a shed attached to house and that shed has a metal pipe which is in contact with earth This pipe is connected to the armoured connector of the cable - is this sufficient equipotential bonding. Circuit has RCD...
  19. D

    New Oil Boiler

    Need a new oil boiler 5 bedrooms 3 bathrooms whats best, combination oil boiler or pressurised tank for hot water whats the best make for oil boilers whats best make for pressurised hot water tanks thanks for help