Search results

  1. J

    Pump for low flow cold water

    Ok, so how does this work as I’m sure the pump should not be on all the time as this would build pressure wouldn’t it do they only work when you call for water
  2. J

    Pump for low flow cold water

    anyone know of a pump i can put from the storage tank in the loft to make the cold water flow a bit better, its so poor from the tank in the loft
  3. J

    air in hot water to front of bungalow

    for some years now the kitchen and small cloakroom always have a problem with air in the hot water, the bathroom is 100 % and never been an issue, No one can seem to get to the bottom of the issue, any ideas ?
  4. J

    Picking up live feed in loft

    Appreciated
  5. J

    Picking up live feed in loft

    Do you think an issue then ? there has been no work done in the loft
  6. J

    Picking up live feed in loft

    No issues with using anything and no shocks or tingle, he said it might be ghosting and he seems it all the time
  7. J

    Picking up live feed in loft

    I had a plumber come to change some pipe work and he advised that the heating pipe work in the loft is picking up electrical feed, it’s all on the beams, cold water tank etc. he was checking with a pen like tool that glowed red, he didn’t seem to concerned but it’s got me concerned, any ideas...
  8. J

    Picking up live feed in loft

    I had a plumber come to change some pipe work and he advised that the heating pipe work in the loft is picking up electrical feed, it’s all on the beams, cold water tank etc. he was checking with a pen like tool that glowed red, he didn’t seem to concerned but it’s got me concerned, any ideas...
  9. J

    Air in hot water pipe for kitchen - bungalow property

    im not sure this pic helps but it shows the pipe coming through the ceiling ( 22 into 15 and back to 22 ) and on the long run to the kitchen strange that only the bends are 15
  10. J

    Air in hot water pipe for kitchen - bungalow property

    So I went in the loft today to see how things are working, the bathroom hot water pulls from different pipes that look to be connected to the CH and off of a pipe that has a vent The kitchen pulls from what looks like the pipe from the top of the cylinder and there is no vent on any run of this...
  11. J

    Air in hot water pipe for kitchen - bungalow property

    ill check this but dont think so the run to the kitchen does t off towards the end to feed the cloakroom
  12. J

    Air in hot water pipe for kitchen - bungalow property

    Already checked, the pipe hasn’t much fall to be honest but is almost as long as the property, when the air is there it’s easily resolved with putting a wet a cover the tap and drawing it out, it then appears a week or so later
  13. J

    Air in hot water pipe for kitchen - bungalow property

    Yes hot water cylinder, tank was new 18 months ago, bathroom is fine,
  14. J

    Air in hot water pipe for kitchen - bungalow property

    i have a gravity fed CH system in a bungalow. The hot water tank is behind the bathroom and cold water in the loft, ( above the bathroom ) The hot water in the bathroom is fine, no air appears at all On the longer run to the front of the property where the kitchen is and cloak room after a few...
  15. J

    Driveway sealents

    Hi, i took advantage over the weekend to seal the driveway with a water based product from universeal. All went down nicely with 2 coats ( wet on wet ) and left the cars off the drive for 3 days to fully cure. the issue i have now is tyre marks, i know that you do get tyre marks occassioanlly...
  16. J

    Auto air valve

    Yes a lot of horizontal pipe work
  17. J

    Auto air valve

    the bigger tank has been in the same place for 30 years so confused as to why this would need raising now, it is higher than the pipework but i would say not by much, a few inches, would the AAV not relieve the air ?
  18. J

    Auto air valve

    Bathroom Is a feed from behind the hot water tank and not from the loft