Search results

  1. A

    baxi combi boiler 105 he need change diaphragm?

    agiles right the diaphrgam letting water pass doesnt cause the leek and the full repair kit will solve it .however these boilers are known to like soaking the electrics on repair so make sure you do it slowly open hot taps to get most of water out the system especially if they are higher than...
  2. A

    Vaillant questions

    check your pressure releif pipe outside isnt leaking if it is then the valve will need replacing and expansion probably depleated which is causing it .when heating up to max temp whats the pressure showing .the system should have been designed and installed so at max pressure doesnt really get...
  3. A

    range tribune ts207 thermostat

    hi can anyone help called out to leak on tribune cylinder at thermostat only a drip so ordered new stat is this wet pocket drip feed only , and does the new stat pushfit seal to the union or does the whole tank need draining and new wet pocket replaced looks like someone stood on stat and...
  4. A

    requirements shared premises

    can any one help . does a domestic shared let require interlinked smoke / heat detectors only or a full fire alarm system . shared let is four rooms only with shared kitchen lounge all rooms ensuite .many thanks sorry just jumped across from combustion chamber and getting some quotes in just...
  5. A

    vaillant hot water

    nice one guys i need all the help i can get at the mo will give it a go .hey that rhyms and will deffinately use combustion chamber from now on cheers.
  6. A

    vaillant hot water

    steady now steady ..calm down lad calm down . believe it or not i am corgi but not very experienced obviously .and when someone gives an opinion theres no point just saying der ok i want to understand the complete logic behind it or it wont make sense and i will learn nothing . vaillant...
  7. A

    GLOW WORM 30CXI BOILER - NUMEROUS PROBLEMS

    unfortunately i agree with the others it means blocked plate heat exchanger however iv had boilers showing faults that just arnt correct sorry not much help i know .glowworm and vaillant tech help and customer service are a joke
  8. A

    vaillant hot water

    yea flow rate is fine and the boiler was great a week ago . dont think its the plate he as the water is hot at first to shown temp on display but gas valve modulates down when water reaches temp but the display stays at say 60 degrees even when water cools and the gas valve should be modulating...
  9. A

    GLOW WORM 30CXI BOILER - NUMEROUS PROBLEMS

    the plate heat exchanger is only in use on hot water demand as the heated water from the central heating main heat exchanger is diverted to it only when a tap is open hence the f14 fault only when you run hot water
  10. A

    Smoke from condensing boiler

    lookup the corgi website and give them a ring they can send an inspector out and if hes not happy he can investigate further and get h.s.e involved if neccesary, looks illegal to me right on the boundary . be prepared to fall out with your neighbours
  11. A

    vaillant hot water

    hi guys any ideas on a vaillant ecomax 800 series combi water demand gets satisfied for about 20 seconds then gas valve modulates down to reduce temp as thermastat shows on display water at set temp though it isnt have changed the domestic hot sensor no good and no fault codes as therm thinks...
  12. A

    worcester lock out

    if you ever need any boiler manuals try goto plumbing . com they have everything
  13. A

    worcester lock out

    forgot to add its a 24i rsf and when starting from reset the hot water works fine time and again unitl boiler goes to heating demand satisfied then nothing works cheers
  14. A

    Cold Heating Radiators Upstairs

    try isolating one of the cold rads drain down and open the valves into a bucket see what the flows like if its good at least its not the pipe work
  15. A

    SCRAP METAL PRICES

    so what are you getting for your copper per kilo if you girls have finished scratching
  16. A

    heating in the bathroom

    what i mean is they could turn the heating off and isolate the bathroom lockshields to the rad and just turn on the electric elements use hot water as normal .hope it helps mate but nobody knows everything there could be a better way good luck..
  17. A

    Cold radiator

    first step deffinately shut off both valves drain rad and dissconnect valves from rad open each valve into a bucket and see what flow of water is like
  18. A

    heating in the bathroom

    why dont you just install electric thermostatic elements into the wet system in the bathroom and they can put on independantly to everything else
  19. A

    worcester lock out

    hi guys hope you can help been looking at a worcester combi 24i when reaching demand goes to lockout and wont refire if you isolate the boiler and turn back on everything works as normal untill demand satisfied again , fan seems fine as does pump and air pressure swith pump and fan overrun as...
  20. A

    Baxi solo 2 boiler problem

    when you heard the humming was it the pump running and were you calling for heating or hot water if it wasnt the pump and the pump doesnt run when calling for heat or water then the switched live has to be checked if there is mains voltage there then the potentiometer will need changing if no...