    Flexible hose on hob

    how many m.i. for hobs are present in houses? none! i thnk as long as you inspect behind an oven, make a note thats its ncs hose, no damage but recommend replacement thats covered you.
  2. L

    Flexible hose on hob

    Flexible hose on a hob . Can this be classed as NCS as long as there is no damage/stress to hose or is it strictly AR regardless of condition? Ta.
  3. L

    electric ovens , gas hobs

    thats what i thought. its a grey area. isolation tap is a compression joint toobehind an oven. hardly accessiable!!! i ve no idea why this transco disconnected the hob. ncs is what id classify it as not i.d.!!!! thanks
  4. L

    electric ovens , gas hobs

    oh hob was installed 5 years ago. surely ncs if discovered,
  5. L

    electric ovens , gas hobs

    hi. for landlord checks do electric ovens have to be pulled out?? ive never done it except for tracing leaks.inspect gas pipe work that is accessible is the reg's is what i adhere to. surely if that was the case any gas pipe behind a panel with screws would have to be inspected!!!i always...
  6. L

    co incident

    ive stopped doing powermaxs ages ago. mainly located in newbuilds over past 5 years with concealed flues and inherient safety probls as outlined by mike the boilerman. there a no. kestons too. if i cant inspect flue route im out of there.
  7. L

    co incident

    does anyone remember a case of a guy who was ex british gas for 20 years. woman died 3 years . it was alleged that he adjusted the premix valve. he wasnt convicted. wondering about ther details as even if the premix was adjusted how did co get back into the flat in this incident?
  8. L

    december work

    hi all. ive only been self employed a while ago so still finding my feet. im getting plenty of repair work as its winter but have noticed my landlords gas cert side of the business has dropped off. i m assuming its just because its december and hardly anyone moves in/out of rental property in...
  9. L

    combustion caps

    hi. im curious. i dont have a plumb centre near by. id like to get a few combustion caps for turbomaxs, glowworm cxi, worcester cdi as ive noticed its increasingly common for these to be missing. !!!!an inspector of my firm went in to a flat , hadnt noticed combustion cap missing and then i go...
  10. L

    electric domestic testing.

    hello.i do alot of gas and epc checks for landlords. im completely ignorant of the electric industry. id like to do domestic pat and electric testing as an addition to gas and epc checks. could you tell me what i require to do this, experience, qualifcation etc many thanks
  11. L

    sub contracting

    hi. im thinking about sub contracting cp12's for social housing sector. just wondering what do i need. got my van, gassafe reg, liability insurance, tools/ analyzer. anything else? should i contact social housing contracters themselves or go through agency? many thanks
  12. L

    gas safe stationary

    extraordinary that they are not providing logoed staionary in any formand corgi are. more extraordinary is that there is no where on the site where engineers can access their details, notify workk etc. what a joke!!!!!!!!!!!!!!!!!!!!!!!!
  13. L

    gas safe stationary

    ta. what are you usuing for cp12's coz i dont know anyone who has gassafe stationary. this is gonna coz alot of probs already. losing work because people dont believe corgi are not in charge!!! what a mess already
  14. L

    gas safe stationary

    evening. does anyone know if the corgi cp12 forms are still valid? im on the gas safe register website and no mention of any kind of cp12 etc etc stationary!! good start for them .ta
  15. L

    performa 24 he

    just wondering. did a few landlords on performas 24he combi. noticed with a few that the hot water cuts out for about 3 sec every minute or so. has anyone come across this before?seen about 6 like this so far.
  16. L

    gas meter changes

    afternoon. thinking of doing gas meter changes in london for few months. anyone what kind of money is around for that in london? thanks
  17. L

    aps faulty

    thanks.what models should i look out for ?
  18. L

    aps faulty

    evening. can a faulty APS cause a combi to overheat? read in a combi fault finding book and cant understand how a aps can cause this??
  19. L

    test pump

    testing a pump.-- 240v going to it, resistence need ohms reading, removing vent plug if water constantly dribbling of vent plug out then the pump is knackered? thanks
  20. L

    cookers

    hi missing plastic temprature conrol knob on hob. would that be AR? testing these new ffd on cookers. how to test? low burner, blow out flame and wait 60 sec for gas to shut off? cheers