Search results

  1. L

    Flexible hose on hob

    Flexible hose on a hob . Can this be classed as NCS as long as there is no damage/stress to hose or is it strictly AR regardless of condition? Ta.
  2. L

    electric ovens , gas hobs

    hi. for landlord checks do electric ovens have to be pulled out?? ive never done it except for tracing leaks.inspect gas pipe work that is accessible is the reg's is what i adhere to. surely if that was the case any gas pipe behind a panel with screws would have to be inspected!!!i always...
  3. L

    co incident

    does anyone remember a case of a guy who was ex british gas for 20 years. woman died 3 years . it was alleged that he adjusted the premix valve. he wasnt convicted. wondering about ther details as even if the premix was adjusted how did co get back into the flat in this incident?
  4. L

    december work

    hi all. ive only been self employed a while ago so still finding my feet. im getting plenty of repair work as its winter but have noticed my landlords gas cert side of the business has dropped off. i m assuming its just because its december and hardly anyone moves in/out of rental property in...
  5. L

    combustion caps

    hi. im curious. i dont have a plumb centre near by. id like to get a few combustion caps for turbomaxs, glowworm cxi, worcester cdi as ive noticed its increasingly common for these to be missing. !!!!an inspector of my firm went in to a flat , hadnt noticed combustion cap missing and then i go...
  6. L

    electric domestic testing.

    hello.i do alot of gas and epc checks for landlords. im completely ignorant of the electric industry. id like to do domestic pat and electric testing as an addition to gas and epc checks. could you tell me what i require to do this, experience, qualifcation etc many thanks
  7. L

    sub contracting

    hi. im thinking about sub contracting cp12's for social housing sector. just wondering what do i need. got my van, gassafe reg, liability insurance, tools/ analyzer. anything else? should i contact social housing contracters themselves or go through agency? many thanks
  8. L

    gas safe stationary

    evening. does anyone know if the corgi cp12 forms are still valid? im on the gas safe register website and no mention of any kind of cp12 etc etc stationary!! good start for them .ta
  9. L

    performa 24 he

    just wondering. did a few landlords on performas 24he combi. noticed with a few that the hot water cuts out for about 3 sec every minute or so. has anyone come across this before?seen about 6 like this so far.
  10. L

    gas meter changes

    afternoon. thinking of doing gas meter changes in london for few months. anyone what kind of money is around for that in london? thanks
  11. L

    aps faulty

    evening. can a faulty APS cause a combi to overheat? read in a combi fault finding book and cant understand how a aps can cause this??
  12. L

    test pump

    testing a pump.-- 240v going to it, resistence need ohms reading, removing vent plug if water constantly dribbling of vent plug out then the pump is knackered? thanks
  13. L

    cookers

    hi missing plastic temprature conrol knob on hob. would that be AR? testing these new ffd on cookers. how to test? low burner, blow out flame and wait 60 sec for gas to shut off? cheers
  14. L

    asd cutoff

    asd on gas fire cutoff time is 60 sec? thanks
  15. L

    mid position valve

    hello. y plan system heating and water work fine independantly. but mid position diverter valve doesnt go to mid position and provide both at same time. what could be the reason? cant be swollen/ stuck ball, prgrammer must be ok as ch/hw work , ?
  16. L

    over gassing

    hi. if a combi boiler was overgassed would the c/h and h/w simply get to temprature quicker and not neccessarily trip overheat/high limit stats? nots not on my acs im sure but just curious
  17. L

    cooker ventilation

    hi guys coild you clear up 2 things before my acs mclarky flue not slealed outside = ar what about inside not sealed but outside bricked up? is extractor ventilation ok for cookers. cant see it corgi book but have a heard from a an engineer that its ok??? cheers
  18. L

    overheating

    was also wondering. combi boilers that are overheating what is the usual first port of call for fault finding? system pressure, f and e not empty and pump working seem like the most obvious ports of call???
  19. L

    flow temp measurement

    since many old boilers dont have fault lights etc is a digital thermometer placed on flow temp the best way to tell if boiler is overheating with these type of boilers? also. when i finish my acs after donkeys in army what stuff do you guys reccommend i carry round for breakdowns.? mant thanks
  20. L

    injectors

    ive heard alot about gas rates /flame pics being affected by damaged injectors. wondering on a room sealed boiler how is it possible for injector to become damaged? thanks
Back