    Fire Rated Spotlights Question (AGAIN)

    Yes in great detail. I question this at the time but wasn't given a reply I was sub-contracting to a building company so unsure of how they applied for planning as im a registered installer i self notify building control via the online system on completion. My problem now is the...
  2. D

    Fire Rated Spotlights Question (AGAIN)

    Right i know this question has been raised over and over again but i just cant find the answer here or via the building regulations. We have recently worked on a garage that has been split to form a utility room this has been split with a firewall. The original door to the garage from the...
  3. D

    High ZS on all circuits

    Yeah mate tested from the henly block fed from the meter.
  4. D

    High ZS on all circuits

    Everything checked for tightness and also for missing the bussbarr as ive come across that before were the bar is behind and just making contact. Gonna check the RCD tomorrow, tight on time today and its an empty house so able to leave power off.. :)
  5. D

    High ZS on all circuits

    The issue is is im getting a reading of 0.45 at the incomer and that added to my R1+R2 is know were near the reading im getting for my circuit ZS readings. Also the circuit ZS reading exceed the maximum permit ZS due to this
  6. D

    High ZS on all circuits

    Hi there, Ive just tested a new installation and getting a ZE of 0.45 on a TN-S system. I'm also getting a ZS at the board of 0.45. Its only a small house so the R1+R2 readings are pretty low.. Sockets 0.22 Lights 0.66 Shower 0.03 Cooker 0.06 The problem im having is when...
  7. D

    Kva to Mw

    In a fashion yes, but not sure that I calculated this right. Its seems low to me. If I have under calculated that would be great as i need as much available watts/amps I can get. From a calculation I did I get that 5000Kva over 3 phases would give around 12,500amps Its doesn't have to...
  8. D

    Kva to Mw

    Hi, If I get a 5000Kva 3 phase supply installed into my building, what would be the maximum available Mw. Ignoring switch gear for now. I have got the figure of 2.8Mw from my calculations. Any help?
  9. D

    what edition was rcds introduced

    cheers for that, Im just pricing some work on a care home, the care home had a periodic inspection in 2006, and remedial work was carried out including new consumer units, ground floor socket and outside circuits, but not one consumer unit or circuit in the whole building offers rcd...
  10. D

    what edition was rcds introduced

    What was the year and edition of the regs that stated sockets that can be used outdoors must be rcd protected?
  11. D

    Energy Saver Bulb flickers when swiched off?

    What i ment was that when originally connected who is to say that it was connected right, does the switch wire go to L? or N? It does matter on Energy saving lamps for some reason, and after switching them round on mine it worked fine
  12. D

    Energy Saver Bulb flickers when swiched off?

    i had this problem all i did was swap my switched live an neutral over in the pendant, they where both black. Just be carefull if there is more than one cable as this may have neutrals in an out aswell as carrying the live to the next fiiting you dont want to put your live in with your neutrals.
  13. D

    What area can a ring circuit cover (Commercial)

    They are feeding very loud speakers, each speaker has its own power supply, the idea of the ring was my from electrician who did say if it was a radial the voltdrop and disconnection time would mean it would require a larger cable, thats why his original idea was a 4mm ring circuit to cover the...
  14. D

    What area can a ring circuit cover (Commercial)

    there will be a around 35 unswitched spurs above a false ceiling which the appliance's are using 0.2amp. the total area is around 950sqm I was thinking of instructing my electrician to wire 3 x 2.5mm t&e ring circuits to cover this. He was talking about wiring 1 x 4mm t&e ring circuit. I...
  15. D

    light switch

    Try This
  16. D

    What area can a ring circuit cover (Commercial)

    In a commercial installation what area in square meters can a ring circuit cover. Thanks
  17. D

    Not allowed gas meter under a sink!

    As explain to me by my electrician. Under a kitchen sink or bath is in zone 0. Zone 0 is Where electric outlets are only permited if they are only accessible via the use of a tool! Luke a bath panal screwed in but you can really screw the sink unit shut can you! He has shown me these...
  18. D

    Not allowed gas meter under a sink!

    Cheers for that lads!!! :D I know that electrical sockets are no longer permited under sinks, which is common sense but this guy really baffled me!
  19. D

    Not allowed gas meter under a sink!

    He told me he actually called corgi technical support or called somebody, to confirm but i couldnt hear anybody on the other end. Just thought that somebody on here will have clue where i can find this information from.
  20. D

    Not allowed gas meter under a sink!

    I work for myself selling and fitting kitchens and last week on a job I called the local corgi registered plumber out of the phone book as I was further away than my regular plumber is willing to travel. I asked him to install pipework for a new hob an move the gas meter tighter into the...