Search results

  1. M

    worcester 24cdi boiler no hot water

    think im just gunna call it beginers luck,and if it goes again put the house up for sale!!!!!
  2. M

    worcester 24cdi boiler no hot water

    Hi, thanks for the helpful advise you were right it was the divertor valve i got a new diaphragm £20 and a set of new o rings and washers £20 and downloaded a worcester manual.four and a half hours later i,d had the valve out stripped it down cleaned it and the water exchanger,fitted the new...
  3. M

    worcester 24cdi boiler no hot water

    Please could someone help me,i have the above boiler the ch works fine but there is no hot water.Ive been told i need a new diaphragm in the divertor valve,however if i run the hot tap slowly the valve does not press the micro switch.If i run the hot tap hard enough it does press the micro...
Back
Top