    hot water system also bleeding into central heating

    There is two check valves built into the body of the pump plan just behind the pump valve flange.check valves just pull out
  2. J

    muddy water from hot water

    is a steel towel rail fitted to the domestic hot water
  3. J

    Megaflo or Range Tribune?

    Fitted lots of Range Tribune cylinders , had no call backs. both good cylinders
  4. J

    radiators getting hot when heating off and hot water on

    I've fitted alot of grunfos pump plans and it seems a big problem with them,i've since gone back to fitting "s" and "y" plans because of this. it seems to me that your check valve has still got dirt in it or it is in some way damage , you can get replacement check valves from the internet.the...
  5. J

    radiators getting hot when heating off and hot water on

    pump plans have two single check valves fitted on both out lets, your heating check valve has dirt inside it, this allows the flow of water to creep to the radiators.
  6. J

    Expansion Valve dischargin

    could be caused by mixer taps with no check valves fitted.or taps mixing hot water with unbalanced cold water which could result in cylinder back pressure.
  7. J

    downstairs bathroom 25m from HW tank

    The return loop would be piped into the bottom of the cold feed to the cylinder. Also you would need to fit a single check valve on the return loop just after the bronze pump.Essex flange would be ideal for feed pipe.
  8. J

    Cold downstairs radiator

    have you tried turning all the rads off except the cold one
  9. J

    downstairs bathroom 25m from HW tank

    you could run a secondary return pipe from the cylinder (hot water tank)to new shower room .using a bronze pump
  10. J

    Glow worm boiler tripping out

    is there thermostatic rad valves on all radiators? if so there should be an automatic bypass fitted on the system some where, it could be that all the thermostatic radiators are shut down not allowing the pump to get rid of the heat in the boiler.
  11. J

    Pipe stat fitted...but

    Is the pipe stat fitted on the flow or return, if on return all the rads will heat up until return water reaches set temp.
  12. J

    Glow worm boiler tripping out

    Check ballvalve in central heating tank is not stuck and therefore not filling the central heating up as it sounds like the whole system is short of water and causing the boiler to over heat and trip off
  13. J

    Water cool in the morning

    The ballvalve in the hot water header tank in the loft would be constantly dripping if there is a leak
  14. J

    Worcester Heatslave 20/25 Overpressuring & red hot radia

    Check Expansion vessel hose for blockage