Search results

  1. G

    Exposed incoming supply

    TVM
  2. G

    Exposed incoming supply

    http://jeremy-gusterson.magix.net I think this will give a picture. Use above link then look in my vacation. Hope it works.
  3. G

    Exposed incoming supply

    My house is fed from overhead cable. Supply in house is TN-C-S. I have a single cable from wooden plyon outside house. Where it attaches to side of house it splits into two (This split can be seen and reached if leaning out a window.) The single cable outer then becomes my neutral and earth...
  4. G

    painting problem

    wall had about 10 days to dry out. don't know about the going off thing cos was not present when applied. Husband thinks deposit was more salty than sandy! area not crumbly. Have sanded down and applied 50/50 PVA - shall see what happens...
  5. G

    painting problem

    Yes thanks. I used a 50/50 mist coat. This has also blistered off.
  6. G

    painting problem

    we had a wall with old plaster on. We have recently had the wall skimmed and in places it reacted and looked like it had sand stuck to the wall! Sanded this off and painted and it blistered and peeled off! HELP please.
  7. G

    new showere and 45a mcb (MK) crackling sound problem

    Hi If you have test tightened all the screws and not found one lose then: remove the busbar, loosen the screws some more and then refit the busbar. It is possible that the screws are tight but the clamp in the RCD/ctt breakers have missed the busbar. The sound you are hearing is arcing...
  8. G

    supply fuse removal

    No. You may however have a very good chance of damaging yourself. Qualified electricans are not ment to pull this fuse although many do. The Elec Supply company should re-fit the fuse and will re-wire it. That is if they are happy with your work. Gus
  9. G

    Security lights

    Onesongrg I have fitted one of these light where you have to put power on then off then on again in order for the PIR to work correctly. It was a while ago but I think I had a fused switch or pull cord type s/w fitted. It should state in the instructions if this is the required procedure to...
  10. G

    Shower RCD ref

    Thanks guys. Thats has has made me :P . I will still use the said RCD. And when people :?: I can just quote the manufacturers instructions. many thanks again. Gus
  11. G

    Shower RCD ref

    Yes I Know about cable size and RCDs or RCBO with showers but I cannot fot the life of me find a reference in the regs. I know it is a high risk cct but my calculation still had a disconnect time of 0.1s with a ccb so why and where is the reference to fit rcd? Gus
  12. G

    Problem wiringVarilight dimmer switch

    Matt Do you have three wires going between the two switches. The Varilight dimmers require this. One of these is a live link so if you only have two core between the switches you are stuck unless you have another live frm the same cct coming to the slave unit.(This would save on the link...
  13. G

    Old house

    Hi romchik. I will help you as everyone else seems to be trying to show you how hard it all is. It is easy, and you do not need all the books described eariler. This is ment to be a DIY forum to help people. Use MK Split load CU. 1.5mm2 cable for lighting cct 2.5mm2 for rng cct...