    Can I improve my DHW Flow rate Vaillant 824

    Does anyone know it is possible to improve the flow rate on a ECOtec824. Can I possibly loose some top end temperature in gain for higher flow rate? Is there some kind of flow restrictor in the cold water supply, if so could I remove this and refit a higher flow rate restrictor on the incoming...
  2. B

    ECOMAX 824 poor DHW flow rate

    Sorry I meant flow restricter not pressure reducer!!!
  3. B

    ECOMAX 824 poor DHW flow rate

    Stripped the DHW HE out today to check for debree from the filter. However came across nothing! I took the flow restrictor out and gave it a good bowing through in both directions. The flow restrictor I would say was way too restrictive but I have nothing to compare it too. The DHW HE was...
  4. B

    ECOMAX 824 poor DHW flow rate

    Seeing you had that exploded diagram of the DV, you wouldnt have the part no. for the item 9, the filter? Been trawling the web to find it but having no luck. Otherwise I'll pop into parts centre tommo!
  5. B

    ECOMAX 824 poor DHW flow rate

    Ah nice, is the flow restricter on the cold inlet of the dhw heat exchanger then? Id best get a new filter as well, if I can.
  6. B

    ECOMAX 824 poor DHW flow rate

    Checked the filter on the water side of the diverter valve earlier. What I found was the remains of a filter! All the gauze has gone and the filter is completly useless! I presume the pieces of filter have got drawn into the dhw h'exchanger. further strip down required!!!!!
  7. B

    ECOMAX 824 poor DHW flow rate

    NICE! will check the filter (item 9) tomorrow, shouldnt take to long. Cheers again dan
  8. B

    ECOMAX 824 poor DHW flow rate

    anyone know where I could get an exploded diagram of said diverter valve?
  9. B

    ECOMAX 824 poor DHW flow rate

    ok dan, will check the diverter valve out. Cheers will let you know how I get on.
  10. B

    ECOMAX 824 poor DHW flow rate

    Not a chance I would tell them to replace it, got plenty of life left in it yet. You can get a whole new D valve for £100, new boiler would cost them ten times as much and some!!!!. I would like to fit them a new boiler as work is work.
  11. B

    ECOMAX 824 poor DHW flow rate

    Not yet, where are they situated? My plan was too turn the mains water of and check the cold supply through. Anothe colleuge of mine said that there could be a restricter on the inlet to the dhw plate h'exchanger.
  12. B

    ECOMAX 824 poor DHW flow rate

    like this.... not that shagged, boiler works very well, apart from rubbish dhw flow!
  13. Untitled

    Untitled

  14. boiler bits

    boiler bits

  15. B

    ECOMAX 824 poor DHW flow rate

    Not got the model number on me at the mo, I've just disscovered this forum. I thought (wronge probably) that the ecotec with the black controlled panel was the VUW model. so it would be turbomax vux 242 eh, i guess. the diverter valve part no. is 011280. There is a flat bladed adjustment...
  16. B

    ECOMAX 824 poor DHW flow rate

    Fitting a bathroom at the moment, but was concerned at the poor hot water flow rate. I measured the flow rate and it is only 5l/min. After sifting through the Vaillant manual I tried to adjust the water section of the divertor valve but was allready in the full flow rate position. I've searced...