  1. C

    toilet waste pipe

    I need to drill a hole for a new toilet waste through a 600mm wall on a very old farm house. The wall is a mixture of boulders (rough slate) and infill. My question is would I be best to use a diamond core bit which I have or a TCT bit for the slate or another method. Any...
  2. C

    RSJ lintel calculations?

    Won't the beam only be supporting the equivalent of one bedroom floor (half of one and half of the other)? Also half of the total ceiling area as long as the ceiling joists are supported on the bedroom dividing wall.
  3. C

    RSJ lintel calculations?

    I seem to remember that the rough check for deflection is: depth should be at least length / 17. You can also check the BS covering weights of building materials (can't remember the number sorry) and the Approved document covering structure for the loads. This will allow you to do the calcs...
  4. C

    Suction

    Many thanks again Jbonding for your help. I have not used bond-it so was not aware of it. Is it a specific plaster pre-treatment?
  5. C

    Suction

    Here is the problem. Four walls of various materials (bonding, sand & cement and painted plaster) due to years of repairs. I am going to skim over as the walls are sound and do not really warrant overboarding. I was planning to PVA the walls to get uniform suction but was not sure exactly...
  6. C

    Qualifications

    Many thanks to all for your advice it is much appreciated. I think I am going to go down the C&G 2381 and 2391 route.
  7. C

    Qualifications

    Hello all, I have just had a change of career and am now renovating and converting domestic properties. I have no formal electrical qualifications and would like to gain the right qualifications to enable me to rewire, test and certify electrical installations in domestic properties. I am...
  8. C

    Overboarding

    Thanks jbonding, I have not seen any signs of damp so I think I will go with Hardwall as I have used it before and was happy with the results. Just out of curiosity is there any reason for using sand and cement other than cost? Many thanks again
  9. C

    Overboarding

    I have to reinstate three originally plastered internal walls after the old render and plaster has been removed (not by me and I have no idea why). I have used dot & dab in the past to overboard internal walls in the past and am happy with this method but I am not sure if this is the...
  10. C

    thermostat for air conditioning

    Also make sure that the the diff on the stat is wide enough to stop the unit short cycling
  11. C

    thermostat for air conditioning

    Make sure it is not a heat pump and that there is no requirement for humidity control. If there is check out Danfoss as suggested in the previous.
  12. C

    Replacement tools

    Thanks for the tip Gcol. I would be interested what you think of the Makita. I found the Li-Ion Makitas on the US web site and had got no further than that so I was not sure if they were available in the UK.
  13. C

    Another SDS Drill question

    Why not try the Bosch PBH 240 RE. I bought one of these after using a friends, it has both SDS and twistlock chucks also rotation stop for chiseling. The cables on these are 3m which really is a bonus. It is only 620W but has served me very well with no problems using 4" diamond bits for...
  14. C

    Replacement tools

    I am looking to replace some of my cordless tools. I have a Ryobi 18V circular saw which was ok for DIY but I am looking for a replacement which will stand full time use. I have been looking at the new Lithium Ion tools coming out. Makita do an 18V Li-Ion saw on Milwakee do v28 Li-Ion...
  15. C

    Cooker wiring

    Many thanks for your help Andrew
  16. C

    Cooker wiring

    The cooker point will be off to the left hand side of the cooker (cooker top at work surface level with a stainless splashback above running the full width of cooker, tiles running from the left hand side above the work surface up to the splashback, the cooker point will be 300mm (unless it has...
  17. C

    Cooker wiring

    I am putting in a dedicated supply for my dual fuel range cooker. The electric power consumption at full load is 4.5kW. I am putting in a 6.0mm supply direct from the consumer unit to a cooker switch (45Amp + 13A socket). I have some questions with regards to this installation that I would...
  18. C

    LV dimmer

    Let me first thank the members of this board and the administrator for a very comprehensive and useful resource. Having read many of these posts I think the wealth of questions and answers has enabled me to come up with a solution to problem but I would like to clarify my solution with you...