    Replace timed fan for inline fan

    This morning I looked at it again with fresh eyes. At the top of the wall was an isolation switch. This I think was the supply for the permanent live, and thus was removed. Using the remaining blue ( Neutral ) Yellow (S-Live) I connected to the new fan. I works real good but a little quite...
  2. J

    Replace timed fan for inline fan

    If the yellow is the swicth live, then could I keep that connected and use the blue ( neutral) and disconnect the red ( permanant live) ? Complete re wire not my first choice as this is quite involving.
  3. J

    Replace timed fan for inline fan

    Thanks for your reply. Please note that I am replacing the fan not having 2 fans. I want to use the existing wiring for the 2 terminal inline fan if possible
  4. J

    Replace timed fan for inline fan

    I am replacing my bathroom wall mounted fan for an inline light fan. Light ok, but when removing old fan I was greeted with the following wires. Supply in Yellow, Blue, Red. Connected to fan Red, Blue, Brown. The new inline fan only has a twin terminal block, Im guessing Live and Nuetral ? Can...