Is it ok to install an RJ45 socket and a 13A socket in opposite sides of a dual galvanised box? Does the galv box provide sufficient separation? What distance does the Cat5e and 2.5 T&E need to be when run down the wall?
It is ok to feed a garage from 2.5mm T&E on 20A MCB which is run in conduit to detached garage 4M away with conduit along fence. Then terminate into old type fuseboard with 5A & 15A circuits for sockets and light? Does it need seperate earth? Or is earth on T&E ok?
£350 to sign work off? pretty expensive i think! NICEIC will charge around £1000 for initial membership registration and 1st yrs membership, so that may be good option. You will need calibrated test equipment though and all relevant regs - onsite guide etc etc
He's not asking if its safe to use, he's asking if the lifespan will be effected??? Or will it dry out and be in the same condition as prior to water exposure?
He just dosnt want to have tools pack up on him a few months down line thats all!
would the components inside not be damaged? would motors etc?
Dosnt a PAT test just prove it is safe to use? How can you tell that things inside havent been damaged???
If a garage has flooded and the drills etc have been exposed to water, the drill not designed for exposure to water ie no suitable IP rating for this, then would this not fail an inspection before testing on a PAT test?
If the items have been exposed to the water would i be right in saying they...
Going to have to have better look next week, looked pretty hard getting back to DB when popped head in yesterday - only doing as favour really normally only do domestic stuff. The DB MCBs are Moeller is there another brand that'll fit the DB as think may have prob getting hold of that type of...
The premises are small but it may be difficult to get feed back to DB for their own circuit as would need to go through concrete floors back to DB. The idea of RCD sockets in conduit may be only option.
I'm a Domestic Spark so would appreciate a little advice from a commercial spark out there...
If adding x2 extra sockets in a office kitchen, do these sockets need RCD protection?
What if they are labelled for kitchen appliances only?
If putting existing circuit on RCBO wouldnt this create...
Just installed some 4W LED lamps into spotlight fitting - when turned off they are flickering! I've checked polarity and it seems fine.
Only other thing i can think of is it has a timeguard timer switch with photocell operating it - would this have something to do with it?
If so how can i...
Are meter tails meant to be protected by RCD if buried beneath plaster?
Meter tails need to be run from outside meter housing to CU in utility but utility will be plastering, buring tails - so if they are not RCd protected its against regs aint it? But if protect with RCD will have against regs...
Two Interlinked Smoke alarms are showing 24v between interlink connection and earth or neutral. They are sounding with no apparant cause - could this 24v on interlink wiring be causes it? The 24v is present on wiring even with smokes not connected
Is they any special requirements in an electrical installation where there is a pool for animals? ie No sockets within 2m
Is there any special requirements for the installation, ie lower RCD, as the animals have lower body resistances?
cheers
Does Emergency Light require a key switch to operate to facilitate testing them? Does regs require them?
Factory Unit got loads of emergency lights in, but no keyswitches to test them, apart from turning MCBs off