    Room thermostat not connecting to CH boiler

    with clock off and stat turned down can you put a pic up of front of boiler and what its doing. And as per country fan do you just have one stat as in you dont have separate controls upstairs and down stairs or underfloor heating ?
  2. G

    Room thermostat not connecting to CH boiler

    i missed the pic of the combi
  3. G

    Room thermostat not connecting to CH boiler

    it will be a faulty motorised valve then , not the stat
  4. G

    Room thermostat not connecting to CH boiler

    does the heating go off when the clock/programmer is set to off
  5. G

    CH Pump Problem

    did you look at the level before draining ? 5 minutes would drop the tank by more than a third
  6. G

    CH Pump Problem

    do it for more than a few seconds but a minute /90 seconds should do it
  7. G

    CH Pump Problem

    drain some water off and see if you can hear the header tank filling up if you cant you have a blocked cold feed
  8. G

    Main soil drain

    if it goes to a shared drain then it could very well be covered for free from your water supplier the rules changed a number of years ago Worth giving them a call
  9. G

    CH Pump Problem

    leave big screw off pump and turn everything on check if the internal screw is spinning freely its very rare the impellor actually comes off. pump making an noise / boiler only staying on for 30 seconds no water out of highest point Do you have a header tank in the loft supplying the boiler ...
  10. G

    What is this bit that's leaking? (Baxi)

    It will be on the flow pipe from the boiler
  11. G

    Old tail pipe stuck in central heater

    hacksaw blade into the hole and do a few cuts taking care not to damage thread in the rad and it will come out using hamer and a flat blade
  12. G

    What is this bit that's leaking? (Baxi)

    No need to put a safety valve back in a black iron plug will do .
  13. G

    What is this bit that's leaking? (Baxi)

    its an old fashioned safety valve from the 60/70`s under all that crude are relief holes it can be taken out and plugged off as they are not required anymore . we used to just cover stuff up and just snatch them . Although the tee is 22mm (or 3/4) the valves came in either 1/2 inch or 3/4 ...
  14. G

    Heated towel rail not working how do I find the valve?

    yep does it look like it has an allen key socket inside it if not do what densso says
  15. G

    Heated towel rail not working how do I find the valve?

    inside the spleen is there an allan key socket
  16. G

    Baxi no heating, Hot water ok ???

    if piezo clicks and lights for HW IF it doesnt for CH it could only be a board fault
  17. G

    Big Water Bucket in the cupboard

    if its supplying a cylinder then its an open vent tank fed cold water then it could have suffered airlocks so someone added a way for air to escape . . No need for an FE tank for heating to be that size and volume also the water looks far too clear /clean. . My thoughts are cylinder
  18. G

    Big Water Bucket in the cupboard

    25 gallon tank would normally be tank fed cold water or feeding a hot water cylinder
  19. G

    Baxi no heating, Hot water ok ???

    you say fire up mode , so does it actually fire . not by any chance turned off the boiler isolating valves by mistake when filling up also sometimes if they have been used lever just spins on spindle and needs taking off and turned on with pliers