  1. G

    Mira 88 leak

    nope nothing you can do except take it apart
  2. G

    Boxing in boiler pipes

    better pic would be from underneath to see what valves etc could be the reason for leaving a bit of room
  3. G

    We have very high water meter readings any ideas please?

    any hot water pipes under suspended floor downstairs or buried in concrete
  4. G

    Dish Washer filling with water randomly

    intermittent inlet valve passing
  5. G

    Help identifying valve function

    you always have an open port . Both ports can never closed at the same time.. And as we know one rad should always be trv free
  6. G

    Help identifying valve function

    the top one is a manual bypass and can be left completely closed as you have a 3 port valve The bottom one is a balancing valve for the HW which from fully closed open it about 1 and half to 2 turns
  7. G

    Can you get thin 22mm pipe insulation?

    because there might not be any room fekme it doesnt take much working out
  8. G

    Gas Meter and boiler pipe sizing

    The 2 wanting over 2 grand for a possible 12 metre pipe run using no more than 150 quid of materials are trying to have your pants down . I would not be entertaining them in anyway . Simple pressure test at the boiler will confirm whether pipe needs upgraded You already have part 22mm pipe...
  9. G

    Baxi Bermuda no CH but HW working

    in the airing cupboard is there two electrical valves attached to pipe work by the pump , possibly 1 with 3 connections
  10. G

    Water splashing out of drain appliance

    your bottom connection is this for a dish washer if so then its probably left a load of gunk in that elbow dismantle it and clean it out
  11. G

    Moving stop tap above floorboards, terraced house

    but denso might just still walk in ;)
  12. G

    Moving stop tap above floorboards, terraced house

    Is it a modern one in the pavement outside ? Its usually easier to just turn off outside
  13. G

    Can you get thin 22mm pipe insulation?

    might not be to prevent potential freezing
  14. G

    Can you get thin 22mm pipe insulation?

    https://www.wolseley.co.uk/product/center-pipe-insulation-22mm-x-9mm-(2m)/ Local plumbcentre off the shelf
  15. G

    New boiler or not?

    Magna cleans are know as magnaleaks within the trade due to how easy they leak after being touched
  16. G

    New boiler or not?

    no it wont , anyone who has been in the trade will have experienced the mass of jelly in the header tank when the gallon containers of fernox was just added to the header tank . It was never got pulled into the system and just turned into gelatinous mass. If putting it in the tank then drain off...
  17. G

    Boiler Issues

    you have boiler issue then and it needs diagnosing by qualified guy
  18. G

    New boiler or not?

    i have fitted systems that were in for decades with no inhibitor and the water was crystal clear when eventually drained for new boilers. Proper installation stops any fresh water/oxygen ingress
  19. G

    Boiler Issues

    what fuse had blown and what further fuses blew ?
  20. G

    Boiler Replacement

    i gave the figure for the 30kw on post 5