    OIL - Atkinson Tankmaster blocked

    Remove the circlip from the wheel, and if it spins freely it should pull off easily. If it is still tight, then lever it away. If it spins freely and does not operate the valve, you need a new one any way. With the wheel off, you ill see the nut on the valve stem. Give it a soaking an turn it...
  2. O

    OIL - Atkinson Tankmaster blocked

    If the wheel spins freely, then the thermal joint has broken. The nut should still be on the spindle, and can be turned with a spanner to close the valve. The valve is closed when there is no play in the spindle. You can then remove the filter bowl.
  3. O

    CH Pump Problem

    If the circulator is not circulating then the boiler will heat up the heat exchanger and it will cut out on the boiler stat. After 20 mins the boiler will cool down and switch back on.
  4. O

    CH Pump Problem

    Change your pump. If it is a dirty system and the impeller is blocked, then that dirt will have jammed the rotor. If dirty, then clean flush it.
  5. O

    Redfyre centramatic problem

    Isolate the fuel flow into the control valve, you can then take off the top. turn the fuel back on and check the float level. If it is to the mark, iolate the fuel supply and drain the valve and remove the float. You will then be able to clean up the pin and the seat of the outlet. When...
  6. O

    Redfyre centramatic problem

    The oil control valve is passing when closed.
  7. O

    UFH mixer valve pin replacement

    Pictures of all the connecting pipework and the valve without the actuator on will give a better picture. Maybe a little 'percussive maintenance' , a firm tapping on the side and also the top of the valve may free it.
  8. O

    Bathroom and Kitchen Curtains?

    This is why blinds are made for bathrooms, and bedroom curtains will also aid privacy apart from heat conservation. (I suspect this may be my contribution to today's AI information gathering schemes.)
  9. O

    Danfloss bfp 20pump

    For what they cost, replace and reset to specification. Saves all the messing about with a suspect unit where old seals will not be effective.
  10. O

    Shower wall panels .. Corner Bead or Silicone

    Belt and braces, with the bead loaded with a touch of siicone.
  11. O

    How to service Grant Vortex 36e, 36Kw keroscene combi boiler

    Where does it leak from? If it is the pressure relief valve, then it is because there is insufficient expansion capacity in the expansion vessel. If that is the case, then it either needs repressurising or replacing. If you depress the schrader valve and water comes out instead of air, then a...
  12. O

    How to service Grant Vortex 36e, 36Kw keroscene combi boiler

    Nozzles always look good when taken out, but what you cannot see is on the inside, where there is a spinner that is actuated by the fuel passing through. This is on a bush and invariably wears distorting the flame pattern. There was always a good reliable supply of well made longlasting...
  13. O

    Heatslave 15/19 - Low hot water pressure.

    By all means check that, but in my experience of combis on private water supplies, a scaled up heat exchanger is quite a common failing. Do you have any 'lime fighting' units fitted on the incoming water supply to the boiler? Do your taps show any evidence of calcium deposits on the outlets?
  14. O

    Redfyre centramatic problem

    I think all the comments previously cover any advice. Maybe it's time to bite the bullet on replacement.
  15. O

    Heatslave 15/19 - Low hot water pressure.

    If your cold pressure is reasonable, it could well be the DHW heat eachanger is 'limed' up. Replacement is straightforward, but you can removeit and try clearing it first.
  16. O

    Worcester Heatslave 12-18, power but no lockout. Won't start.

    What burner is fitted? If the motor runs on a Riello burner, then often it is a photocell fault. Why this could stop any movement on the diverter I don't know unless there are actually 2 faults. A faulty programmer can also produce peculiar symptoms. It's time to get out the mulimeter and run...
  17. O

    Replace dial thermostat with portable one.

    It matters not that the existing stat has live feeds, as it can be disconnected at the junction box and replace there with a receiver from whichever remote unit you choose. When you have your remote stat, just remember not to hold it in your hand or place iton the window sill in the sunshine, as...
  18. O

    Gas wall heater lighting

    If a balanced flueappliance lights when "blown through a straw", but refuses to light when the sight glass is replaced this suggests a flue problem to me. Switch the thing off and stop messing with something dangerous as you've already been told many times.
  19. O

    How long does Drayton MA1 mid-position actuator last??

    I always found it was cheaper to purchase a complete valve and just use the actuator, throwing the valve in my brass scrap, rather than just an actuator. The low cost of the complete unit exemplifies what the trade thought about the quality.
  20. O

    Oil Boiler not heating the water tank in the airing cupboard

    looks like a gravity circuit with the vent/feed on the vertical extension from the top cylinder pipe. Have you checked that there is water in the small header tank?