  1. L

    Range Powermax 155x - HW works but not CH

    thanks all, the return pipe by the boiler was blocked. problem solved now.
  2. L

    Range Powermax 155x - HW works but not CH

    additional findings so far- * The CH pump works and the flow manifold gets hot. * By closing all rad valves, and turning just one TRV on, the return pipe by the base of that particular rad gets hot. (but not the pipe connected to the TRV, which is definitely the flow pipe) * all the...
  3. L

    Range Powermax 155x - HW works but not CH

    Thanks. Have checked all trvs- dont think they are the problem. Turned the speed up to level 3- also tried opening up the rads one by one and i do get heat from 2-3 rads closest to the boiler. (which is an improvement!) also replaced the pump but didnt help any further...
  4. L

    Range Powermax 155x - HW works but not CH

    As an update, i have found the manifolds. All branches from the inlet manifold are hot, but all from the outlet are cold. I also notice now that the towel rads, which are the only ones that work, are also part of the same circuit. Any comment on would be welcome!
  5. L

    Range Powermax 155x - HW works but not CH

    I think so, it's pretty clearly marked. In any case I've checked both pumps and they are both spinning. :(
  6. L

    Range Powermax 155x - HW works but not CH

    Yeah it's spinning and all the valves do open fully.
  7. L

    Range Powermax 155x - HW works but not CH

    ... and as far as I can tell the pump is working fine.
  8. L

    Range Powermax 155x - HW works but not CH

    Thanks Tony, I think the towel rads must be on a different circuit since they are the only ones that work, though I'm not sure then what is pumping hot water into them. I don't think my boiler has a motorised valve - could not locate one. (Unless someone who knows powermaxes will tell me...
  9. L

    Range Powermax 155x - HW works but not CH

    I have a Powermax 155x (open vented) which was installed in 2004 when the apartment was newly built. I’ve been getting hot water fine all year, but no heating to my radiators since trying to turn it on for the first time this winter. Here are my findings so far; • CH pump seems to be running...
  10. L

    Powermax 155x concept

    Hi guys, Just moved into a flat (built in 2005) to find a powermax 155x sitting in it. I've done basic research online and so far understand that it's a tricky and odd boiler with an identity crisis that is a thermal store AND a combi (sort of). As some of you will know, on the boiler...