  1. C

    Vaillant VRC 430f cycling issues - a solution?

    I agree with David. The setting for 'pump blocking' or as on my VRC 430 'pump delay time' will shut the boiler down from time to time and this is on top of the boiler shutting down when the flow temp overshoots or flow/return difference becomes too small. My suggestion in addition to the...
  2. C

    Noise from Boiler But Only When Heating Water Cynlinder

    Problem solved! For those who may be interested, I drained down the system, did a cold flush, refilled and treated with Fernox F1. Its been almost a week now and the system is running very quite. Why did I choose this course of action? Well, first, the two plumbers I contacted did not...
  3. C

    Noise from Boiler But Only When Heating Water Cynlinder

    UPDATE I couldn't test the AAV fitted to the pump as the cap does not fully unscrew. However, I did tinker around a bit and I think it may be air or some sort of gas causing the problem. Here's what I did - 1. Start boiler with just DV for rads open - Initially what sounds like a...
  4. C

    Noise from Boiler But Only When Heating Water Cynlinder

    Tony, I did test this yesterday but only the one fitted to the heating circuit which seems to be working fine which was expected as I replaced this a few months back as the previous one leaked like an incontinent pensioner. I'm bit reluctant to test the one fitted to the side of the pump...
  5. C

    Noise from Boiler But Only When Heating Water Cynlinder

    Forgive my ignorance, but what are revolver circuits and how would I determine their size? With ref to the noise, the boiler is at s.24 when it starts and the noise continues through s.27. When i checked this yesterday, the noise started when the flow temperature reached 65c. Cheers.
  6. C

    Noise from Boiler But Only When Heating Water Cynlinder

    Oh, I didn't mention that boiler control is a VRC430 weather compensator, and the hw cylinder stat and DVs are wired through a VR65 control centre. Consequently the boiler knows if the demand is for heating or hot water. Within the boiler configuration menus, setting d.19 (pump speed) is set...
  7. C

    Noise from Boiler But Only When Heating Water Cynlinder

    I have a two year old Vaillant ecoTEC Plus 615 system boiler which runs the heating and charges a Megaflow hot water cylinder. I've noticed a rushing noise (like theres debris in the water) from it when its heating the cylinder. It kicks in when the flow temperature reaches approx 75c -80c...
  8. C

    Help I’ve got some silicone in my gloss!

    I had almost finished the gloss coat on my new door frame when I dragged the brush over a remnant of silicone from sealing around the bath. The paint immediately started to mottle. I have stopped painting and am allowing it to dry. Could anyone help with advice on how to recover from this...
  9. C

    Basin Mixer Tails

    Hi. I'm changing my basin mixer tap and the replacement has fixed 10mm chrome plated tails. I'm after some fitting tips and have some questions - The best way to bend the tails? Can I cut the tails down without damaging the chrome? Should I remove the chrome where the compression...
  10. C

    Air Admittance Valve Below Flood Level ???

    I’m refitting my bathroom and it would be helpful if I could slightly lower the Air Admittance Valve (AAV). I note from this forum and other www sources that the AAV should be fitted above the flood level of the highest appliance or above the trap level of the highest appliance. These may...
  11. C

    Vailant vrDIALOG

    Thanks for the posts It can be used for a lot more. You can access all the diagnostics, settings and fault codes remotely from your PC; you can configure some of the VRC400/430, etc settings; and you can capture all sorts of data and plot it into graphs, etc.
  12. C

    Vailant vrDIALOG

    Hi. Can anyone confirm that vrDIALOG 810/2 will work with my system which comprises - ecoTEC plus 615, VR 65 and VRC 430? Its compatibility with the VRC 430 that I worried about as its quite new. If so, can the software access and configure the Holiday programme usually set on the VRC...
  13. C

    System Balancing Help

    I have already reduced it from 2 to 1 and it made no perceivable difference. OK, will do. Thanks very much for all your help.
  14. C

    System Balancing Help

    That’s interesting. I have the Vaillant sensor and VR65, but didn’t fit the sesnor thinking the only advantage would be the ability to adjust the HW temp from the VRC430. What are the benefits of using the sensor and would I need to adjust some settings on the boiler ie storage part load...
  15. C

    System Balancing Help

    Thanks, you're a star! I set the heating part load (d.0) to 8kW as I don't have the system set to charge HW when heating. Early signs are good - the boiler runs continuously until the house has reached the set temperature and it reaches the set temperature a lot quicker than before. Before...
  16. C

    System Balancing Help

    I have found another calculator (still can't get the other working even on a different computer!) It has come up with 5.83 KW required, ignoring DHW charging. Yep. Lucky I managed to convince the plumber to go for the smaller one! The smallest (612) operates 5-12 Kw. I forgot to mention...
  17. C

    System Balancing Help

    Thanks for the links. The building calculator isn't working at the moment, but I have calculated the combined rad outputs to be approx 6KW. I must say that a temp drop of 20C would seem unachievable for my system. Can this really be achieved with a condensing boiler set...
  18. C

    System Balancing Help

    Thanks for the reply. No, I haven’t calculated the heating load and don’t know how to! Are you suggesting the rads may be too small or the boiler too large? I had the old boiler (Potterton Ultra 2 12Kw) replaced in the summer. My plumber wanted to replace it with an Ecotec plus 618, but...
  19. C

    System Balancing Help

    I have an Ecotec plus 615 providing heat to 10 rads most of which are quite small. The flow and return temperature difference to the boiler and most of the rads is approx 3-4C. Is that OK? I have tried to better balance the rads, but I have to almost completely close the LSVs to increase...
  20. C

    Ecotech Plus 831 Combi with VRC430 + VR81

    Setting times can only be done on the VRC430. The VR 81 is a thermostat with basic controls to change the current temp or the operating mode. Unless you have two heating zones - upstairs/downstairs, I think the VR81 would become the master thermostat overriding that in the VRC430...