Search results

  1. veloman

    jub outside render

    ah well,we have got a start date so its a bit late now to worry,we have seen 3 houses the company have done and all were excellent,we have seen one in k rend, it had only been done a week and some of the corner beads were coming away ( a hard sell firm from brum) not ours
  2. veloman

    jub outside render

    The total outside wall area is 117 sq mts, and of that about 12 sq mts is glass, 9 windows 1 door
  3. veloman

    jub outside render

    any comments on jub/jubizol products,we need to render the outside of the house ,end terrace,big gabble end,and have been quoted 5750 plus vat to do it, the scaffs already up, and that seems a bit much to me,any comments thoughts greatfully received
  4. veloman

    insulateing solid brick walls

    and kingspan on there web site put the batten on the wall and the kingspan on top of that ,so you have a air gap against the cold wall so who do you believe ? I am now at a loss as to which way to go.
  5. veloman

    insulateing solid brick walls

    I have just read the celotex pdf again and i stand to be corrected,but the way I read it you put the celotex against the brickwork and the battens on top of the celotex then apply your plaster board to the battens so your air gap is between the plaster board and the celotex,ie air gap on the...
  6. veloman

    insulateing solid brick walls

    the way we were going to do it, ie 25mm laths on the wall celotex over and then board over the top gives a void of 25mm ish behind the celotex,or did you mean something else,sry if I've missed your point.
  7. veloman

    insulateing solid brick walls

    AJ, I only said T Break 50mm because there is a firm advertiseing it on the net at 50mm and it was a very good price,I shall get more details before I order it
  8. veloman

    insulateing solid brick walls

    I had a look at the procter stuff ,but to be honest the figures went over the top of my head , I thought the T break was the stuff to use,so could some one confirm that it is ok for the purpose of wall insulation,I dont want to buy 40 sheets then find out its not quite the stuff for the job,thanks
  9. veloman

    insulateing solid brick walls

    thanks for that AJ,so the celotex T break is ok for the job,we are using the T break board, as we have 2675mm ceilings and can use a 2700 p/board to cover so we will have no horizontal joints in the face,thanks again
  10. veloman

    insulateing solid brick walls

    I just new that was coming.........thanks for that
  11. veloman

    insulateing solid brick walls

    Hi guys, I have removed all the plaster from 2 ground floor rooms ready for the outside walls to be insulated ,ie 25mm battens,celotex T break 50mm board,then 12.5 mm plaster board over,my question is, do I put any thing in the gap between the wall and the celotex,the plasterer says he puts...
  12. veloman

    who to ask? what profession

    hi guys this is my first post so if its in the wrong place,sorry,I live in a 1905 semi that has been renderd at some point,all the plaster has been blown of the exposed gable end wall which is always cold /wet,it gets all the weather that comes down the hill, its solid 9 inch brickwork, we...
Back