    Ideal Logic Combi 30+, possible issue?

    Forgot to mention this in my OP, when the boiler is cycling on/off the display shows "super efficiency". I initially thought the the cycling was a feature of the super efficiency mode.
  2. M

    Ideal Logic Combi 30+, possible issue?

    Funny you should mention that. When I first tried the CH a few weeks ago now, the boiler was not responding to the thermostat/timer at all, i.e. as soon as I switched it to winter mode, it came on straight away, even with the timer set to constant off. I did some searching and found out about...
  3. M

    Ideal Logic Combi 30+, possible issue?

    I've recently moved into a new place with an Ideal Logic Combi 30+. The boiler was brand new and works great. However, once the set temp on the room thermostat has been met, the boiler will constantly cycle on and off, only staying lit for a matter of seconds, and then when it's almost completed...
  4. M

    Miele W865 Motor repair help

    Hi Zipper, many thanks for your reply! Whilst I was waiting for a response, I tried drilling out the existing screw and this must have weakened it enough, as I was then able to remove it using the flat blade screwdriver, and as you said, I used a bearing puller to remove both the pulley and...
  5. M

    Miele W865 Motor repair help

    Hi, The bearings on our W865's motor have gone and I am trying to replace them. I have successfully replaced the one closest the commutator but having difficulty replacing the one at the other end of the shaft. To get at the other one, you need to remove the belt pulley, which is held in...
  6. M

    Miele W828

    I too would also just like to say thank you to all the contributors of this thread. On Monday this week our 9 year old Miele W865 stopped working and presented the flashing "rinses" light fault. After finding this thread, I ordered the £2 6.3A fuse from Farnells in hope of being able to fix...
  7. M

    HW too hot, thermostat set at 60c

    Stat is fitted a third of the way up, immersion is definitely not on.
  8. M

    HW too hot, thermostat set at 60c

    Yes, the foam is cut away exposing the bare copper. The tank is full of hot water, yet the copper surface where the stat goes is cold to the touch, the pipe from the top of the cylinder that feeds the taps is very hot. As stated in my op, I have already tried changing the tank stat.
  9. M

    HW too hot, thermostat set at 60c

    Hi, I'm having some trouble with my HW, the thermostat on the hot water cylinder is set to 60c but the water coming out of the taps is much hotter, almost scalding hot. I've replaced the thermostat with a new one and the problem remains. Currently the water is too hot, however removing the...